============================================================================= Run Date: SEP 22, 2014 Designation: VBEC*1*74 Package : VBEC - VBECS Priority: Mandatory Version : 1 SEQ #73 Status: Released Compliance Date: SEP 30, 2014 ============================================================================= Subject: SEPTEMBER 2014 WINDOWS UPDATES FOR VBECS Category: - Informational Description: ============ This patch serves to alert VA facilities using the Vista Blood Establishment Computer Software (VBECS) that Microsoft Windows Updates are available for immediate installation. If the VBECS servers are serviced by a second group, i.e. a Regional Data Center, it is the responsibility of the local IRM support person for VBECS to ensure that all parties who need to see this Update Information for 'their' VBECS system sees it. The local support should follow local policies to forward such information to their Server Administrators. Sites who have not installed VBECS have no action to take with this informational patch. This patch is released with a seven (7) day compliance because the updates address security vulnerabilities in Microsoft Windows. Failure to comply with the installation of Windows Updates could expose the VBECS servers and software to security threats. BLOOD BANK CLEARANCE ===================== EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch VBEC*1.0*74 contains changes to a package referenced in BBM Team Review of VISTA Patches. This patch does not alter or modify any VistA Blood Bank software design safeguards or safety critical elements functions. RISK ANALYSIS: Changes made by patch VBEC*1.0*74 have no effect on Blood Bank software functionality, therefore RISK is none. Windows Updates ================ If your servers are maintained at a data center, ignore this section since data center personnel will install updates. These Microsoft Windows Update patches must be installed on the VBECS servers: KB2918614 KB2993651 KB2972207 KB2977629 KB2894843 KB2894842 KB2972215 KB2972214 KB2973115 KB2894845 KB890830* *Note: Windows Update KB890830 is a malicious software removal tool and does not appear in the list of applied patches after installation. The VBECS development team must test every Microsoft Windows update. Once the development team is satisfied that the update causes no adverse effects, Clinical Product Support (CPS) will give the sites permission to apply the update by releasing this informational patch. Updates are approved with Windows Server Update Service. Approved updates will be downloaded to your servers automatically. However, a server administrator must install the updates locally. Windows Update instructions: ============================ 1) Since most updates require a reboot, coordinate a time with the Blood Bank manager to apply the updates. All Blood Bank users must be logged off the VBECS server before updates can begin. 2) At the agreed upon down time, log on to the VBECS cluster as a user with server administrator privileges. 3) Use the Cluster Administrator Tool to verify which node is active (Windows Updates should not be installed on an active node): a. Click on START, CONTROL PANEL, ADMINISTRATIVE TOOLS, CLUSTER ADMINISTRATOR. b. If the OPEN CONNECTION TO CLUSTER window appears, enter the VBECS cluster name and click OK. c. When Cluster Administrator has opened click on the folder titled "Groups". d. The server name listed on the right side under the Owner column is the "Active" node. e. Record the server name listed under Owner, this is the active node. The other server in the VBECS cluster is the passive node. f. Log off of the VBECS cluster server once the server name of the active node is determined. 4) Log on to the passive node of the VBECS cluster as a user with server administrator privileges. 5) Verify all users (other than the user installing the Windows updates) are off the VBECS server (do not proceed until all users are logged off): a. Open Task Manager: click on START, RUN; Type TASKMGR and click OK. b. Select the USERS tab to see the users who are logged on to the server. c. Right click on each user's name and click on SEND MESSAGE to send a message to the user asking them to log off the system. d. Wait for all users to logoff. If a user's status is Disconnected, right click the user's name and click on LOG OFF. e. Close TASK MANAGER after all users are logged off the server. 6) A yellow shield shaped icon should appear in the System Tray (lower right corner of desktop) indicating updates are available for installation. 7) If the yellow shield shaped icon fails to appear after waiting one minute, perform the following steps: a. Click on START, RUN. b. Type WUAUCLT.EXE /DETECTNOW and click OK. c. The yellow shield shaped icon can take up to 30 minutes to appear after entering the WUAUCLT.EXE /DETECTNOW command. d. If the icon does not appear after 30 minutes, click on START, ADMINISTRATIVE TOOLS, SERVICES. e. Right-click the service named "Automatic Updates" and select RESTART. f. If the yellow shield icon does not appear within 5 minutes, contact the VA Service Desk (VASD) or file a Remedy ticket. 8) Click on the yellow shield shaped icon in the System Tray. 9) Leave Express Install selected. Click INSTALL. 10) When the update process is complete, you may be prompted to reboot. Reboot the server at this time. 11) After the reboot is completed (this may take several minutes), log on to the passive node that is now fully patched. Open the Cluster Administrator tool and perform these steps in order: a. Expand the Groups folder. b. Right click the VBECS Group TEST and select TAKE OFFLINE. c. Right click the VBECS Group PROD and select TAKE OFFLINE. d. Right click the Group 1 and select TAKE OFFLINE. e. Right click the Group 0 and select TAKE OFFLINE. f. Right click on the Cluster Group and select MOVE GROUP - wait until the group is ONLINE before proceeding to the next step (this may take up to 5 minutes). g. Right click on each remaining groups and select MOVE GROUP (VBECS Group TEST, VBECS Group PROD, Group 1, and Group 0). h. Right click on Group 0 and select BRING ONLINE - wait until the group is ONLINE before proceeding to the next step (this may take up to 5 minutes). i. Right click on Group 1 and select BRING ONLINE. j. Right click on VBECS Group PROD and select BRING ONLINE. k. Right click on VBECS Group TEST and select BRING ONLINE. l. Examine the Resources folder. All resources should be owned by the server that has just been patched (making it the active node). m. Close Cluster Administrator. 12) Log off the patched server which is now the active node. 13) Log on to the unpatched server and repeat steps 5-10. 14) At this point, if the Server Windows Update process is complete and there are no outstanding issues, notify the Blood Bank Manager that the VBECS system is once again available for use. If any issues are encountered, contact the VA Service Desk (VASD) or file a Remedy ticket. ======================================================================== NOTE: Do not change the system! The U.S. Food and Drug Administration classifies this software as a medical device. Unauthorized modifications will render this device an adulterated medical device under Section 501 of the Medical Device Amendments to the Federal Food, Drug, and Cosmetic Act. Acquiring and implementing this software through the Freedom of Information Act require the implementer to assume total responsibility for the software and become a registered manufacturer of a medical device, subject to FDA regulations. Adding to or updating VBECS software without permission is prohibited. Routine Information: ==================== No routines included. ============================================================================= User Information: Entered By : Date Entered : SEP 18, 2014 Completed By: Date Completed: SEP 19, 2014 Released By : Date Released : SEP 22, 2014 ============================================================================= Packman Mail Message: ===================== No routines included