$TXT Created by R at MNTVBB.DOMAIN.EXT (KIDS) on Monday, 04/30/18 at 09:11 ============================================================================= Run Date: JUN 28, 2018 Designation: MD*1*61 Package : MD - CLINICAL PROCEDURES Priority: Mandatory Version : 1 SEQ #43 Status: Released Compliance Date: JUL 30, 2018 ============================================================================= Associated patches: (v)MD*1*58 <<= must be installed BEFORE `MD*1*61' Subject: CP FLOWSHEET DATE RANGE SELECTOR, MOUSE WHEEL, AND NETWORK HELP FILE Category: - Other - Routine Description: ============ This patch fixes the following bugs in Clinical Procedures (CP) Flowsheets: 1. When opening the Date Range Selector in CP Flowsheets, the calendar that displays the month does not display the full month. The column for Saturday is either fully or partially obscured. 2. In CP Flowsheets, if the user spins the mouse wheel over the Windows desktop or another running application while Flowsheets has keyboard focus, it may cause the program to cycle through either the list of available flowsheets or the list of available locations (depending on where the user is in the software). 3. When running CP Flowsheets from a network drive or shared network folder, the user can't access the help file. NOTE: Patch MD*1*61 includes a new Graphical User Interface (GUI) executable for CP Flowsheets. Defect Tracking System Ticket(s) & Overview: -------------------------------------------- 1. CA-SDM R17135139FY18 - Clinical Procedure Flowsheets Date Range Selector. Problem: -------- When opening the Date Range Selector in CP Flowsheets, the calendar that displays the month does NOT display the column for Saturday. Only Sunday through Friday are visible to the user. It is possible for a user to click on arrows beside the Today button to move the date into the Saturday column. However, this is neither intuitive nor efficient. Resolution: ----------- The Date Range Selector form was widened sufficiently for both calendars to be fully visible. 2. INC0275439 - Mouse scrolling creates errors Problem: -------- In CP Flowsheets, if the user spins the mouse wheel over the Windows desktop or another running application while Flowsheets has keyboard focus, it may cause the program to cycle through either the list of available flowsheets or the list of available locations (depending on where the user is in the software). Resolution: ----------- The Delphi code was updated so that scrolling the mouse wheel while the mouse is pointing off the application does not affect combo boxes. 3. INC0452105 - Network help file for CP Flowsheets Problem: -------- When CP Flowsheets is run from a network drive or network shared folder, the help file cannot be accessed. This is due to changes in Windows security that don't allow a program that is run off a network to open help files that aren't on the local computer. Resolution: ----------- The first time the user attempts to access the help file, the file is downloaded to the user's local hard drive. Then it can be used normally. Test Sites: ----------- VA Maryland HCS VA Northern Indiana HCS Software and Documentation Retrieval Instructions: -------------------------------------------------- This software is being released as a PackMan message distributed through FORUM, combined with a ZIP file containing the client GUI files. Files and documentation pertaining to this patch are available. The preferred method is to retrieve files from download.vista.domain.ext. This transmits the files from the first available server. Sites may also elect to retrieve files directly from a specific server. Sites may retrieve the software and documentation directly using Secure File Transfer Protocol (SFTP) from the ANONYMOUS.SOFTWARE directory at the following OI Field Offices: Hines: domain.ext Salt Lake City: domain.ext Please refer to the "CP Flowsheets (MD*1.0*61) Deployment, Installation, Back-Out, and Rollback Guide" for patch and GUI installation and set-up information. This document is available on the VA Software Document Library (VDL) at: http://www4.domain.ext/vdl/ Title File Name FTP Mode ----------------------------------------------------------------------- CP Flowsheets (MD*1.0*61) Deployment, md_1_p61_ig.pdf Binary Installation, Back-Out, and Rollback Guide To obtain the updated client software, use SFTP to retrieve MD_1_61.ZIP from one of the OI Field Offices' ANONYMOUS.SOFTWARE directories. File Name Retrieval Format --------- ---------------- MD_1_61.ZIP Binary Zip File Contents Description File Version ----------------- ----------- ------------ CPFlowsheets.exe Client 1.0.61.1 CPFlowsheets.cnt Client CNT file CPFlowsheets.hlp Client help file Patch Installation: Pre-Installation Instructions: ------------------------------ Clinical Procedures users should be off the system when this patch is installed. Installation will take less than 5 minutes. This patch should be installed during non-peak requirement hours. Installation Instructions: -------------------------- 1. Choose the PackMan message containing this patch. 2. Use the INSTALL/CHECK MESSAGE option on the PackMan menu. 3. From the Kernel Installation & Distribution System menu, select the Installation menu. 4. From the Installation menu, select Backup a Transport Global and when prompted for the INSTALL NAME enter the patch MD*1.0*61. This option will create a backup message of any routines exported with this patch. It will not backup any other changes such as DDs or templates. If for any reason the patch is to be rolled back, this backup will be required to restore the patch's routine(s) to the pre-installation version(s). 5. From this menu, you may select to use the following options (when prompted for INSTALL NAME, enter MD*1.0*61). a. Verify Checksums in Transport Global - This option will allow you to ensure the integrity of the routines that are in the transport global. b. Print Transport Global - This option will allow you to view the components of the KIDS build. c. Compare Transport Global to Current System - This option will allow you to view all changes that will be made when the patch is installed. 6. From the Installation menu, select the Install Package(s) option and select the patch: MD*1.0*61. 7. If prompted, "Want KIDS to Rebuild Menu Trees Upon Completion of Install?", respond NO. 8. When prompted "Want KIDS to INHIBIT LOGONS during install? NO//", respond NO. 9. When prompted "Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO//", respond NO. Post-Installation Instructions: ------------------------------- Post-installation routine MDPOST61 is provided which updates Clinical Procedures with the expected version number for CP Flowsheets. Back-out/Rollback Strategy: -------------------------- In the event of a catastrophic failure, the Facility CIO may make the decision to back-out the patch. It is imperative that you have performed a backup of the routine included in this patch prior to installation. Please reference the CP Flowsheets (MD*1.0*61) Deployment, Installation, Back-Out, and Rollback Guide for back-out/rollback instructions. Routine Information: ==================== The second line of each of these routines now looks like: ;;1.0;CLINICAL PROCEDURES;**[Patch List]**;Apr 01, 2004;Build 1 The checksums below are new checksums, and can be checked with CHECK1^XTSUMBLD. Routine Name: MDPOST61 Before: n/a After: B1645038 **61** ============================================================================= User Information: Entered By : Date Entered : APR 20, 2018 Completed By: Date Completed: JUN 27, 2018 Released By : Date Released : JUN 28, 2018 ============================================================================= Packman Mail Message: ===================== $END TXT