$TXT Created by at MNTVBB.DOMAIN.EXT (KIDS) on Tuesday, 03/11/14 at 09:33 ============================================================================= Run Date: JUL 01, 2014 Designation: EN*7*93 Package : EN - ENGINEERING Priority: Mandatory Version : 7 SEQ #89 Status: Released Compliance Date: AUG 01, 2014 ============================================================================= Subject: CORRECT UNDEFINED ERROR WITH ENTER/EDIT ROOM PLANNING DATA MENU OPTION Category: - Routine Description: ============ This patch addresses the following issue: The user is receiving an error when deleting an entry using the Enter/Edit Room Planning Data [ENSP-PLAN1] menu option. Associated NSR(s): ================== N/A Associated Remedy ticket(s): ============================ 1. INC000000784455 - FMUT1^ENSP6 *DA Participating Test Sites: ========================= Lebanon VAMC Salisbury VAMC San Francisco VAMC Remedy Overview: ================ 1. INC000000784455 Problem: -------- The user is receiving an error when deleting an entry using the Enter/Edit Room Planning Data [ENSP-PLAN1] menu option. This is happening because the DA variable is "killed" in the DIE call. Resolution: ----------- Modified routine ENSP6 (FMUT1^ENSP6), setting variable ENDA before the DIE call. This allows for the protection of the DA variable which was "killed" in the DIE call. Installation Instructions: ========================== If installed during the normal workday, it is recommended that the Engineering users be off the system. Other VISTA users will not be affected. Install Time - less than 2 minutes. 1. Choose the PackMan message containing this patch and invoke the INSTALL/CHECK MESSAGE PackMan option. 2. From the Kernel Installation & Distribution System menu, select the Installation menu. 3. From this menu, you may elect to use the following options (When prompted for the INSTALL NAME, enter EN*7.0*93): a. Verify Checksums in Transport Global - This option will allow you to ensure the integrity of the routines that are in the transport global. b. Print Transport Global - This option will allow you to view the components of the KIDS build. c. Compare Transport Global to Current System - This option will allow you to view all changes that will be made when this patch is installed. It compares all components of this patch (routines, DD's, templates, etc.). d. Backup a Transport Global - This option will create a backup message of any routines exported with this patch. It will not backup any other changes such as DD's or templates. 4. Use the Install Package(s) option and select the package EN*7.0*93. 5. When Prompted "Want KIDS to INHIBIT LOGONs during the install? NO//", respond NO. 6. When Prompted "Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO//", respond YES. a. When prompted "Enter options you wish to mark as 'Out of Order':", enter the following option: ENTER/EDIT ROOM PLANNING DATA [ENSP-PLAN1] b. When prompted "Enter protocols you wish to mark as 'Out of Order':", just press . Routine Information: ==================== The second line of each of these routines now looks like: V ;;7.0;ENGINEERING;**[Patch List]**;Aug 17, 1993;Build 2 The checksums below are new checksums, and can be checked with CHECK1^XTSUMBLD. Routine Name: ENSP6 Before: B4773264 After: B4913374 **93** ============================================================================= User Information: Entered By : Date Entered : FEB 07, 2013 Completed By: Date Completed: JUN 25, 2014 Released By : Date Released : JUL 01, 2014 ============================================================================= Packman Mail Message: ===================== $END TXT