============================================================================= Run Date: NOV 30, 2023 Designation: ISI*1.1*110 Package : ISI - ISI IMAGING Priority: Mandatory Version : 1.1 SEQ #1 Status: Released Compliance Date: JAN 02, 2024 ============================================================================= Associated patches: (v)MAG*3*255 <<= must be installed BEFORE `ISI*1.1*110' (v)ISI*1.1*0 <<= must be installed BEFORE `ISI*1.1*110' Subject: ISI RAD REPLACEMENT FOR VISTARAD Category: - Other - Routine - Data Dictionary Description: ============ This patch will allow sites to run the ISI Rad software within the VistA Imaging suite of applications. ISI Rad is replacing the VistARad software which will no longer be supported 30 days after the compliance date for the MAG*3.0*341 and ISI*1.1*110 patches. The ISI Rad functionality and user interactions are virtually the same as VistARad, however, there are some minor cosmetic changes and changes to certain behaviors. In addition, some new features have been added to the product. Some of these new features are available based on Site Parameters settings and/or User-level settings. New Features: Feature Description Optionality -------------------------------------------------------------------------- Favorites Each user can maintain a personal list of exams for permanent or temporary use (e.g., clinically interesting exams; rounds, tumor boards) Advanced The user can create an ad hoc exams list using a dynamically defined query Default Exams The user can select a custom list for Site List Clinician display at startup ISI Rad users may enter Configurable or view notes for a Radiology exam. The notes are displayed only in ISI Rad's Report/Requisition window; radiology staff or other clinical specialist users of ISI Rad have access to this feature. 64-bit port ISI Rad is a 64-bit application; the program has access to much greater computer memory, to better support large studies and program performance The new features and other changes are further described in the Release Notes ISI Rad Replacement for VistARad (ISI Rad Conversion Release Notes.PDF) NOTE: MAG*3.0*341 is required to utilize ISI Rad software." ISI*1.1*110 must be installed before MAG*3.0*341. Patch Components: -------------------------- Files & Fields Associated: File Name (Number) Field Name (Number) New/Modified/Deleted -------------------------------------------------------------------------- ISIJ DYNAMIC QUERY STATS (#23450) New SESSION (#.01) New User (#1) New N-FULLSCANS (#2) New N-RESCANS (#3) New SCANS (#4) multiple New SCAN TERMS (#.01) New FULLSCAN (#1) New N-SECONDS (#2) New DAYS OFFSET (#3) New START DAYS BACK (#4) New DAYS TOTAL (#5) New N-RESULTS (#6) New N-WAITING (#7) New N-EXAMINED (#8) New N-INTERP (#9) New N-COMPLETE (#10) New N-OTHER (#11) New DATE (#5) New ISIJ FAVORITES (#23451) New USER NAME (#.01) New RADIOLOGY EXAM (#1) multiple New EXAM ID STRING (#.01) New KEYWORD-1 (#1) New KEYWORD-2 (#2) New NOTES (#3) New ISIJ EXAM NOTES (#23453) New EXAMID (#.01) New NOTES (#1) multiple New TIMESTAMP (#.01) New USER (#2) New FLAG (#3) New NOTE TEXT (#4) New Forms Associated: Form Name File Number New/Modified/Deleted ---------------- ---------------- --------------------- N/A Mail Groups Associated: Mail Group Name New/Modified/Deleted ----------------------- ------------------------------ N/A Options Associated: Option Name Type New/Modified/Deleted ------------- ------ -------------------------- Query Stats Inquiry Run Routine New [ISIJ QUERY STATUS INQUIRE] Protocols Associated: Protocol Name New/Modified/Deleted -------------------- -------------------- N/A Security Keys Associated: Security Key Name ------------------------- ISIJ ASSIGN EXAMS-VIEW ALL - Allows a Radiologist user to view all assigned exams, regardless who is assigned. This only works on exam list #9802 ALL UNREAD ASSIGNED EXAMS, or any other system list custom programmed to behave in the same manner. Templates Associated: Template Name Type File Name(Number) New/Modified/Deleted ------------- ---- ------------------ -------------------- ISIJ QUERY STATS Print ISIJ DYNAMIC QUER New STATS (#23450) Remote Procedures Associated: Remote Procedure Name New/Modified/Deleted ---------------------- --------------------- ISI GET RAD DX CODES New ISI GET RAD STANDARD REPORTS New ISI GET RAD STANDARD TEXT New ISIJ ASSIGN ENABLE New ISIJ DYNAMIC QUERY New ISIJ FAVORITE New ISIJ GET RAD TECHS New ISIJ LOCK REPORT New ISIJ NOTES New ISIJ RAD EXAM UPDATE New ISIJ RAD RPT DETAIL New ISIJ REPORT ENTER New Parameter Definitions Associated: Parameter Name New/Modified/Deleted ---------------------- ----------------------------- N/A Additional Information: ------------------------------ Blood Bank Team Coordination: There are no changes that will impact the Blood Bank software. New Service Requests (NSRs): N/A Patient Safety Issues (PSIs): N/A Test Sites: -------------- VA Sites: Birmingham VA Medical Center, Birmingham, AL Change Order-CHG0386799 Manila VA Outpatient Clinic, Manila, PI Change Order-CHG0409063 IHS Sites: Chinle Comprehensive Health Care Facility, Chinle, AZ Kayenta Health Center, Kayenta, AZ Phoenix Indian Medical Center (PIMC), Phoenix, AZ Software and Documentation Retrieval Instructions: -------------------------------------------------------------------- The software for this patch is being released using a host file. The host file is available at the following location: /srv/vista/patches/SOFTWARE/ISI1_1P110.KID ISI1_1P110.KID Kernel Installation and Distribution System (KIDS) build for ISI*1.1*110 Other Software Files: This release also includes other software files. Other software files can be obtained by accessing the URL: https://download.vista.domain.ext/index.html/SOFTWARE File Title File Name Format -------------------------------------------------------------------------- ISI_Rad_1.1.1.228 ISI Rad Application Binary _Setup_x64.exe Documentation describing the new functionality is included in this release. Documentation can be obtained at https://download.vista.domain.ext/index.html/SOFTWARE Documentation Title File Name -------------------- ---------- ISI1_1P110_PATCH_DESCRIPTION.PDF Patch Description for ISI*1.1*110 ISI1_1P110_DIBORG.PDF Deployment,Installation, Back-Out,and Rollback Guide for ISI*1.1*110 ISI_RAD_ CONVERSION_RELEASE_NOTES.PDF ISI*1.1*110 Release Notes ISI1_1P110 README.TXT Patch ReadMe file Patch Installation: ------------------------ Pre/Post Installation Overview: Pre-Installation Instructions: VistARad users must not be on the system during the installation. Other users may be on the system although it is recommended that it be installed during non-peak hours to minimize potential disruption to users. This patch should take less than 5 minutes to install. Installation Instructions: 1. Use the Load a Distribution option contained on the Kernel Installation and Distribution System Menu to load the Host file. When prompted to "Enter a Host File:" enter /srv/vista/patches/SOFTWARE/ISI1_1P110.KID 2. From the Kernel Installation and Distribution System Menu, select the Installation Menu. From this menu, A. Select the Verify Checksums in Transport Global option to confirm the integrity of the routines that are in the transport global. When prompted for the INSTALL NAME enter the patch or build name. (ex. ISI*1.1*110) B. Select the Backup a Transport Global option to create a backup message. You must use this option and specify what to backup; the entire Build or just Routines. The backup message can be used to restore the routines and components of the build to the pre-patch condition. i. At the Installation option menu, select Backup a Transport Global ii. At the Select INSTALL NAME prompt, enter your build ISI*1.1*110 iii. When prompted for the following, enter "R" for Routines or "B" for Build. Select one of the following: B Build R Routines Enter response: Build iv. When prompted "Do you wish to secure this message? NO//", press and take the default response of "NO". v. When prompted with, "Send mail to: Last name, First Name", press to take default recipient. Add any additional recipients. vi. When prompted with "Select basket to send to: IN//", press and take the default IN mailbox or select a different mailbox. vii. Repeat step ii for each build in the host file. C. You may also elect to use the following options: i. Print Transport Global - This option will allow you to view the components of the KIDS build. ii. Compare Transport Global to Current System - This option will allow you to view all changes that will be made when this patch is installed. It compares all of the components of this patch, such as routines, DDs, templates, etc. D. Select the Install Package(s) option and choose the patch to install. i. If prompted 'Want KIDS to Rebuild Menu Trees Upon Completion of Install? NO//', answer NO. ii. When prompted 'Want KIDS to INHIBIT LOGONs during the install? NO//', answer NO. iii. When prompted 'Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO//', answer NO. iv. When prompted 'Delay Install (Minutes): (0 - 60): 0//',answer 0. Sample Installation ------------------------- Select Installation Option: INstall Package(s) Select INSTALL NAME: ISI*1.1*110 1/10/23@10:27:31 => ISI patch 1.1*110 (companion to VA patch 3.0*341) -- ISI Rad; replaces This Distribution was loaded on Jan 10, 2023@10:27:31 with header of ISI patch 1.1*110 (companion to VA patch 3.0*341) -- ISI Rad; replaces VistARad ;Created on Jan 05, 2023@21:20:49 It consisted of the following Install(s): ISI*1.1*110 Checking Install for Package ISI*1.1*110 Will first run the Environment Check Routine, ISIJINS1 Install Questions for ISI*1.1*110 Incoming Files: 23450 ISIJ DYNAMIC QUERY STATS 23451 ISIJ FAVORITES 23453 ISIJ EXAM NOTES Want KIDS to Rebuild Menu Trees Upon Completion of Install? NO// Want KIDS to INHIBIT LOGONs during the install? NO// Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO// Enter the Device you want to print the Install messages. You can queue the install by enter a 'Q' at the device prompt. Enter a '^' to abort the install. DEVICE: HOME// HERE Complete ISI*1.1*110 Install Started for ISI*1.1*110 : Jan 10, 2023@10:29:41 Build Distribution Date: Jan 05, 2023 Installing Routines Jan 10, 2023@10:29:41 Installing Data Dictionaries: Jan 10, 2023@10:29:41 Installing PACKAGE COMPONENTS: Installing SECURITY KEY Installing PRINT TEMPLATE Installing REMOTE PROCEDURE Installing OPTION Jan 10, 2023@10:29:41 Running Post-Install Routine: POST110^ISIJINS1 Attaching RPCs to the 'MAGJ VISTARAD WINDOWS' option... ISI GET RAD DX CODES ISI GET RAD STANDARD REPORTS ISI GET RAD STANDARD TEXT ISIJ ASSIGN ENABLE ISIJ DYNAMIC QUERY ISIJ FAVORITE ISIJ GET RAD TECHS ISIJ LOCK REPORT ISIJ NOTES ISIJ RAD EXAM UPDATE ISIJ RAD RPT DETAIL ISIJ REPORT ENTER RPCs have been successfully attached. Updating Routine file... Updating KIDS files... ISI*1.1*110 Installed. Jan 10, 2023@10:29:41 Install Completed Post-Installation Instructions: N/A Back-Out/Roll Back Plan: --------------------------------- Client Uninstall: --------------------- If it is necessary to uninstall the ISI*1.1*110 ISI client, use the Uninstall option from Programs and Features within Windows Control Panel to uninstall ISI application. Then install the previous version of VistARad which was included in MAG*3.0*255. KIDS Uninstall: -------------------- **Note** If the site is rolling back to the VistARad application, the MAG*3.0*341 and ISI*1.1*110 KIDS package must be uninstalled. Select MailMan Menu Option: REad/Manage Messages Read mail in basket: IN// (37 messages, 8 new) Last message number: 45 Messages in basket: 37 (8 new) Enter ??? for help. IN Basket Message: 1// ??Backup of ISI All Messages Search *=New/!=Priority...................Subject............Lines.From......Read /Rcvd 1. * N/A * [56399] 02/20/23 Backup of ISI*1.1*1 729 PATCH,USER Search finished. Enter message number or command: 1 Subj: Backup of ISI*1.1*110 on Feb 20, 2023 [#56399] 02/20/23@08:18 729 lines From: PATCH,USER In '* N/A *' basket. Page 1 -------------------------------------------------------------------------- ----- $TXT Created by PATCH,USER at IMGDEM02.DOMAIN.EXT (KIDS) on Monday, 02/20/23 a t 08:18 Warning: Installing this backup patch message will install older versions of routines and Build Components (options, protocols, templates, etc.). Please verify with the Development Team that it is safe to install. $END TXT