$TXT Created by at DAYT17.FO-BAYPINES.DOMAIN.EXT (KIDS) on Friday, 02/26/16 at 10:02 ============================================================================= Run Date: MAY 09, 2016 Designation: LR*5.2*466 Package : LR - LAB SERVICE Priority: Mandatory Version : 5.2 SEQ #369 Status: Released Compliance Date: JUN 09, 2016 ============================================================================= Associated patches: (v)LR*5.2*444 <<= must be installed BEFORE `LR*5.2*466' Subject: ACCESSIONING ISSUES IN LRWLST Category: - Routine Description: ============ This patch will address the following items: 1. Users unable to enter results for accessioned lab tests marked as uncollected. 2. The accessioning process is causing erroneous test nodes to be set into the LAB ORDER ENTRY file (#69). Associated NSR: ============== N/A Associated Remedy Ticket: ======================== 1. INC000001074620 - Accessioned lab tests are marked as uncollected 2. INC000001218249 - Accessioning creates erroneous nodes in file #69 Duplicate: INC000001239113 Participating Testing Sites: =========================== Central Plains HCS Lexington VAMC Tampa VAMC Blood Bank Impact: ================= EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*466 does not contain any changes to the VISTA BLOOD BANK Software as defined by ProPath standard titled: BBM Team Review of VistA Patches. EFFECT ON BLOOD BANK FUNCTIONAL REQUIREMENTS: Patch LR*5.2*466 does not alter or modify any software design safeguards or safety critical elements functions. RISK ANALYSIS: Changes made by patch LR*5.2*466 have no effect on Blood Bank software functionality, therefore RISK is none. VALIDATION REQUIREMENTS BY OPTION: Because of the nature of the changes made, no specific validation requirements exist as a result of installation of this patch. Remedy Ticket Overview: ====================== 1. INC000001074620 Problem: ------- When using option "Multipurpose accessioning" [LRQUICK], all tests on a specimen number in LAB ORDER ENTRY file (#69) that can be accessioned will be accessioned. However, if one or more of the tests on the specimen number cannot be accessioned because there is no Accession Area defined for the test, then the specimen number will show as uncollected and results will not be able to be entered for the tests on the specimen number that were successfully accessioned. Solution: -------- Modify routine LRWLST to mark the specimen number as collected once the specimen number has gone through the accessioning process. Routines: LRWLST 2. INC000001218249 Problem: ------- If an order is placed for a lab test that is a panel test which has as one of its components another panel test, the accessioning process for this lab order will result in an erroneous test node being set into the LAB ORDER ENTRY file (#69). Solution: -------- Modify routine LRWLST to not set the erroneous test node in file #69 when the situation described above occurs. Routine: LRWLST ====================== INSTALLATION INSTRUCTIONS ====================== The install time for this patch is less than 2 minutes. This patch may be installed when Laboratory users are on the system. 1. Use the 'INSTALL/CHECK MESSAGE' option of the PackMan menu. This option will load the KIDS patch onto your system. 2. The patch has now been loaded into a Transport global on your system. You now need to use KIDS to install the transport global. 3. On the 'Kernel Installation & Distribution System' Menu (KIDS), select the 'Installation' menu. 4. Use the 'Verify Checksum in Transport Global' option and verify that all routines have the correct checksums. 5. On the KIDS menu, under the 'Installation' menu, use the following options: Print Transport Global Compare Transport Global to Current System Backup a Transport Global If you wish to preserve a copy of the routines exported in this patch prior to installation, you should use the 'Backup a Transport Global' option at this time. You may also compare the routines in your production account to the routines in the patch by using the 'Compare a Transport Global to Current System' option. 6. Use the 'Install Package(s)' option under the 'Installation' menu and select the package 'LR*5.2*466. When prompted 'Want KIDS to INHIBIT LOGONs during the install? NO//, choose 'NO'. When prompted 'Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO//', choose 'NO'. Routine Information: ==================== The second line of each of these routines now looks like: ;;5.2;LAB SERVICE;**[Patch List]**;Sep 27, 1994;Build 2 The checksums below are new checksums, and can be checked with CHECK1^XTSUMBLD. Routine Name: LRWLST Before: B35513968 After: B35147101 **46,65,100,121,153,202,290, 424,444,466** Routine list of preceding patches: 444 ============================================================================= User Information: Entered By : Date Entered : OCT 26, 2015 Completed By: Date Completed: APR 27, 2016 Released By : Date Released : MAY 09, 2016 ============================================================================= Packman Mail Message: ===================== $END TXT