============================================================================= Run Date: DEC 13, 2019 Designation: MAG*3*226 Package : MAG - IMAGING Priority: Mandatory Version : 3 SEQ #185 Status: Released Compliance Date: JAN 14, 2020 ============================================================================= Subject: Clinical Capture Delphi Upgrade Category: - Routine Description: ============ MAG*3.0*226, a patch that provides fixes to VistA Imaging Clinical Capture. This patch addresses the following issues: 1. Teledermatology images are not getting moved to Tier 2 storage. 2. VistA Imaging environment upgrade Delphi XE8 to Delphi 10.2.3 Tokyo. 3. OK button on Select New progress notes is not highlighted for saved Configurations. 4. When entering progress notes, scroll bar is not working. 5. Progress Notes columns disappear when navigating past first screen. Patch Components: ----------------- MAG3_0P226.KID - Kernel Installation and Distribution System (KIDS) build for MAG*3.0*226 - New MAG3_0P226_Clincal_Capture_Setup.exe - Clinical Capture client installation file - New MAG3_0P226_Clinical_Capture_Install.msi - Clinical Capture push installation file - New MAG3_0P226_DIBORG.pdf - Deployment, Installation, Back-Out, and Rollback Guide for Patch 226 - New Files & Fields Associated: File Name (Number) Field Name (Number) New/Modified/Deleted ------------------ ------------------- -------------------- N/A Forms Associated: Form Name File Number New/Modified/Deleted --------- ----------- -------------------- N/A Mail Groups Associated: Mail Group Name New/Modified/Deleted --------------- -------------------- N/A Options Associated: Option Name Type New/Modified/Deleted ----------- ---- -------------------- N/A Protocols Associated: Protocol Name New/Modified/Deleted ------------- -------------------- N/A Security Keys Associated: Security Key Name ----------------- N/A Templates Associated: Template Name Type File Name (Number) New/Modified/Deleted ------------- ---- ------------------ -------------------- N/A Remote Procedures Associated: Remote Procedure Name New/Modified/Deleted --------------------- -------------------- N/A Parameter Definitions Associated: Parameter Name New/Modified/Deleted -------------- -------------------- N/A Additional Information: ----------------------- Blood Bank Team Coordination: N/A New Service Requests (NSRs): N/A Patient Safety Issues (PSIs): N/A Defect Tracking System Ticket(s) & Overview: 1. Defect 967341 (Trouble Ticket INC4765823) Teledermatology images are not getting moved to Tier 2 storage Problem: -------- When capturing DICOM images to a Teledermatology consult, the images are not getting added to the Background Processor Jukebox queue for transfer to Tier 2 storage. Additionally, if capture has Abstracts Created set to false in Clinical Capture, Teledermatology Images are not getting added to the Background Processor abstract queue. Resolution: ----------- Modified the code to add DICOM Images captured to a Teledermatology consult to the Jukebox and Abstract Queues. 2. Story 789521 VistA Imaging environment upgrade Delphi XE8 to Delphi 10.2.3 Tokyo Problem: -------- This task upgrades the environments for Clinical Capture from Delphi XE8 to Delphi 10.2.3 Tokyo. Resolution: ----------- The version of Delphi used to build Clinical Capture has been upgraded to Delphi 10.2.3 Tokyo. 3. Defect 1078755 (Trouble Ticket INC6185305) OK button on the create new progress note window is not available for saved configurations. Problem: -------- For saved configurations, the OK button on the Create New Progress Notes window is no longer highlighted without selecting a consult title first, which should have been saved with the configuration. Resolution: ----------- The OK button on the Progress Notes screen is highlighted. Made change to hold Note Title Name coming from the selected saved "Progress Note Configuration" to be compared against a complete list of National Progress Note Titles. 4. Defect 1078765 (Trouble Ticket INC6186970) When creating a new progress note, the scroll bar on the list of note titles is not working. Problem: -------- On the progress note screen, user is facing issues selecting the progress note and using vertical scroll bar. Resolution: ----------- A coding change was made to ensure retention of the National Progress Note Title from the National Progress Note Titles vs Patient Title list. This change ensures the correct spelling of a Note Title is always used to do a search when scrolling through the list. 5. Defect 1118727 Progress Notes columns disappear when navigating past first screen. Problem: -------- On the Progress Note screen, the predetermined columns are displayed on the first screen, but when navigating to different tabs all other Progress Note columns disappear forcing the user to exit and reopen the application for information to display correctly. Resolution: ----------- Added code to ensure the view style is changed from "List" to "ReportStyle" to reinstate the column headers. Software and Documentation Retrieval Instructions: -------------------------------------------------- Documentation describing the new functionality and/or a host file containing a build may be included in this release. Sites may retrieve the software and/or documentation directly using Secure File Transfer Protocol (SFTP) from the ANONYMOUS.SOFTWARE directory on server download.vista.domain.ext Documentation can also be found on the VA Software Documentation Library at: https://www.domain.ext/vdl/ Patch Installation: ------------------- Supported Client Versions: When MAG*3.0*226 is released, the list of supported versions of Clinical Capture will change: Client Versions Supported: 3.0.226 3.0.233 3.0.216 Client Versions No Longer Supported: 3.0.215 3.0.211 3.0.189 Pre/Post Installation Overview: MAG*3.0*226 must be installed on the VistA System and on 64-bit workstations on which the VistA Imaging Applications will be used. This patch must be installed by the compliance date. This patch may be installed with users on the system although it is recommended that it be installed during non-peak hours to minimize potential disruption to users. This patch should take less than 5 minutes to install. Verify that the previous patch in the Supported Client Versions section has been installed. Note: All released VistA Imaging patches must be installed on the VistA system before installing MAG*3.0*226. Installation Instructions: The actual KIDS installation will take less than one minute. 1 On the VistA system, access the Kernel Installation and Distribution System Menu [XPD MAIN]. 2 Run the Installation option [XPD INSTALLATION MENU]. 3 Load the KIDS file by performing the following steps: a. Run the Load a Distribution option [XPD LOAD DISTRIBUTION] to load the KIDS distribution. b. When prompted, enter the path and file name MAG3_0P226.KID of the Patch 226 KIDS file. c. When prompted to continue with the load, enter YES. A Distribution OK! message will be displayed when the load is complete. 4 After loading the KIDS file, use the following options to verify the contents of the patch and to back up any affected routines. a. Verify Checksums in Transport Global [XPD PRINT CHECKSUM] - Run this option to ensure the integrity of the routines in the patch. b. Compare Transport Global to Current System [XPD COMPARE TO SYSTEM] - Run this option to view all changes that will be made when the patch is installed. All components (routines, options, and so on) in the patch will be compared. c. Backup a Transport Global [XPD BACKUP] - Run this option to create a backup message of any routines exported with the patch. It will NOT back up any of the other changes. 5 After performing the load and any optional verification steps, install the KIDS file by performing the following steps: a. Run the Install Package(s) [XPD INSTALL BUILD] option. b. When prompted for the install name, enter MAG*3.0*226. c. Answer NO to the following prompts: Want KIDS to Rebuild Menu Trees Upon Completion of Install? NO// Want KIDS to INHIBIT LOGONs during the install? NO// Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO// 6 When installation is finished, an Install Complete message will be displayed. VistA Imaging Clinical Capture Client Installation Instructions Note: The Clinical Capture Application is only supported on Windows 7 and 10 operating systems. Other operating systems are not officially supported. Clinical Capture is distributed as an MSI and EXE installation. The MSI is intended for sites that want to do a push installation (using SCCM or another tool). The EXE is intended for use to install on a single workstation. The MAG3_0P226_Clinical_Capture_Setup.exe file can be installed manually on workstations as described in the Single Workstations Installation section in the VistA Imaging System Installation Guide. Post-Installation Instructions: N/A Back-Out/Roll Back Plan: ------------------------ Uninstalling the Application: If it is necessary to uninstall the MAG*3.0*226 client, use the Uninstall option from Programs and Features within Windows Control Panel to Uninstall: VistA Imaging Clinical Capture. Then install the previous version of Clinical Capture which was included in MAG*3.0*233. KIDS Uninstall: If it is necessary to uninstall the MAG*3.0*226 VistA KIDS, then select the Kernel Installation & Distribution System menu option, Backup a Transport Global, see the Installation Steps section, where step 4c must be done before installing the patch. Administrators will need to use the PackMan function INSTALL/CHECK MESSAGE. Check the MailMan messages for the backup message sent by the Backup a Transport Global function executed prior to the patch install. 1. Select the message shown below: Backup of MAG*3.0*226 install on 2. Select the Xtract PackMan option. 3. Select the Install/Check Message option. 4. Enter Yes at the prompt. 5. Enter No at the backup prompt. There is no need to back up the backup. Enter message action (in IN basket): Ignore// Xtract PackMan Select PackMan function: ? Answer with PackMan function NUMBER, or NAME Choose from: 1 ROUTINE LOAD 2 GLOBAL LOAD 3 PACKAGE LOAD 4 SUMMARIZE MESSAGE 5 PRINT MESSAGE 6 INSTALL/CHECK MESSAGE 7 INSTALL SELECTED ROUTINE(S) 8 TEXT PRINT/DISPLAY 9 COMPARE MESSAGE Select PackMan function: Select PackMan function: 6 INSTALL/CHECK MESSAGE Warning: Installing this message will cause a permanent update of globals and routines. Do you really want to do this? NO// YES Routines are the only parts that are backed up. NO other parts are backed up, not even globals. You may use the Summarize Message option of PackMan to see what parts the message contains. Those parts that are not routines should be backed up separately if they need to be preserved. Shall I preserve the routines on disk in a separate back-up message? YES// NO No backup message built. Line 2 Message #43934 Unloading Routine MAGXXXX (PACKMAN_BACKUP) Select PackMan function: Routine Information: This section lists modified routines for the VistA KIDS build. For each routine, the second line will contain the following information: ;;3.0;IMAGING;**[Patch List]**; Mar 19, 2002;Build 1;Feb 15, 2017 CHECK1^XTSUMBLD is used to generate the checksums. Routine Checksums Routine Checksum Checksum Patch List Before After MAGIP226 New 4110407 **226** MAGGTU4C 5780139 4965467 **93,94,106,117,122, 129,140,151,178,189, 211,215,223,233,226** Routine MAGIP226 is an installation routine that is automatically deleted after the KIDS installation. Routine Information: ==================== The second line of each of these routines now looks like: ;;3.0;IMAGING;**[Patch List]**;Mar 19, 2002;Build 8 The checksums below are new checksums, and can be checked with CHECK1^XTSUMBLD. Routine Name: MAGGTU4C Before: B5780139 After: B4965467 **93,94,106,117,122,129,140, 151,178,189,211,215,223,233, 226** Routine Name: MAGIP226 Before: n/a After: B4110407 **226** Routine list of preceding patches: 233 ============================================================================= User Information: Entered By : Date Entered : SEP 16, 2018 Completed By: Date Completed: NOV 25, 2019 Released By : Date Released : DEC 13, 2019 ============================================================================= Packman Mail Message: ===================== No routines included