============================================================================= Run Date: FEB 25, 2004 Designation: MAG*3*36 Package : MAG - IMAGING Priority: EMERGENCY Version : 3 SEQ #18 Status: Released Compliance Date: MAR 26, 2004 ============================================================================= Associated patches: (v)XU*8*335 <<= must be installed BEFORE `MAG*3*36' Subject: DICOM Maintenance for Kernel patch XU*8*335 Category: - Routine Description: ============ This patch, MAG*3*36, will correct the error that occurs on the Digital Imaging and Communication in Medicine (DICOM) Gateways after the Kernel patch XU*8*335 is installed on the VistA server. The error is encountered when the DICOM Gateway performs a FileMan look-up in the Institution file (#4). The Kernel patch, XU*8*335, introduces a new routine (XUMF333) that is used to screen Institution file entries and this routine does not exist on the DICOM Gateway. This patch will move the XUMF333 routine on each of the DICOM Gateways. The patch consists of the following files: MAG_30P36.KID - Kernel Installation & Distribution System (KIDS) application to be installed on hospital database. MAGDCM.RTN - DICOM Image and Text gateway software. To receive this patch, a site must have their Site Agreement on file with and approved by the VistA Imaging Group. Once the required documents are received and approved, software will be available on the Imaging FTP server under Software\Software_Released\Mag3_0p36 folder. For information concerning the status of a site, contact Kathy Trombetta via phone (301-734-0357) or email (Kathy.Trombetta@med.va.gov). Test Sites: ================ Columbia, SC Portland, OR Mountain Home, TN White River Junction, VT Fayetteville, NC NOIS Entries: ================ PHO-0104-61167 CAH-0204-30909 ROUTINE SUMMARY: ======================================= The following is a list of the routine(s) included in this patch. The second line of each of these routine(s) will look like: ;; 3.0;IMAGING;**36**;13 February 2004 CHECK^XTSUMBLD results Routine name After Patch Patch List ============ ============ =========== MAGDROUT 5343680 **10,36** MAGIPS36 4705155 **36** MAGDVRSN 3941242 **1,7,9,26,21,10,36** Routine MAGIPS36 is a post installation routine that is deleted at the end of the KIDS install. Routine MAGDROUT was modified to include a reference to routine XUMF333. Routine MAGDVRSN is located on the DICOM Gateway and is used to display the number of patches installed on the Gateway. INSTALLATION INSTRUCTIONS: ========================== Note: Patch XU*8*335 is a REQUIRED BUILD for this KIDS distribution. Installation will take less than one minute; verification will take less than 5 minutes. 1. From the Kernel Installation and Distribution System Menu, select the Installation menu. 2. Use the Kernel Installation and Distribution System Menu option to load the MAG_30P36.KID. 3. From this menu, you may elect to use the following options (when prompted for the INSTALL NAME, enter MAG*3.0*36). a. Backup a Transport Global - this option will create a backup message of any routines exported with the patch. It will NOT backup any of the other changes. b. Compare Transport Global to Current System - this option will allow you to view all changes that will be made when the patch is installed. It compares all components of the patch (routines and options). c. Verify Checksums in Transport Global - this option will allow you to ensure the integrity of the routines that are in the transport global. 4. Use the Install Package(s) option to select the package MAG*3.0*36. 5. When prompted "Want KIDS to Rebuild Menu Trees Upon Completion of Install? Yes// " respond "NO". 6. When Prompted to "Want KIDS to INHIBIT LOGONs during the install? NO//" respond "NO". 7. When prompted "Want to DISABLE Scheduled Options, Menu Options, and Protocols? YES//" respond "NO". DICOM Gateway installation instructions for MAGDCM.RTN file: ====================================================== 1) Use a telnet session to 127.0.0.1. 2) Provide the access and verify codes as prompted. 3) Select the System Maintenance menu option and then select the Programmer's Mode menu option. 4) Provide the programmer's access code. (This code was setup during the initial installation of the DICOM software.) 5) The computer prompt should have [DCM,DCM]; this prompt will indicate whether or not you are in the correct UCI. If you are not please exit and go back to step 1. 6) In programmers mode execute the Routine Restore program (^%RR) to restore the routines in MAGDCM.RTN. This file contains two routines. 7) Provide the correct full path for the MAGDCM.RTN 8) The following is an example: [DCM,DCM]>D ^%RR MSM - Routine Restore Utility Enter input device : Host File Server File Name >: F:\3_0PATCH36\MAGDCM.RTN Routine(s) saved at 07:43 AM 02/13/2004 Header comment is: DICOM Gateway MUMPS routines Build V3.0p36Build520 Selective restore? (allows rename) : NO Restoring... MAGDROUT MAGDVRSN 2 Routines restored. [DCM,DCM]> Verification: =========== To verify that the correct version has been installed use the menu option on the DICOM Gateways. The path is the following: 4- System Maintenance, 1 - System Operation, 4 - Display the Version of the Software. This is "IMAGING 3.0" created on 06-November-2003 Installed patches: Patch 1: 28-March-2002 Patch 7: 03-June-2002 Patch 9: 12-March-2003 Patch 21: 31-October-2003 Patch 10: 06-November-2003 Patch 36: 13-February-2004 Download Kernel routine on the DICOM Gateway: ============================================== To download the XUMF333 routine on the DICOM Gateway use the following menu option: 4 - 'System Maintenance' 2 - 'Gateway Configuration and DICOM Master File' 9 - 'Download Current Radiology and MAS Routines' Perform the above procedures on all the DICOM Text and Image Gateways at your site. Routine Information: ==================== ============================================================================= User Information: Entered By : BARRIOS,LUCILLE Date Entered : FEB 12, 2004 Completed By: DEMOEL,ED Date Completed: FEB 20, 2004 Released By : LOVING,MANLEY Date Released : FEB 25, 2004 ============================================================================= Packman Mail Message: ===================== No routines included