============================================================================= Run Date: MAY 04, 2023 Designation: MAG*3*352 Package : MAG - IMAGING Priority: Mandatory Version : 3 SEQ #240 Status: Released Compliance Date: JUN 05, 2023 ============================================================================= Associated patches: (v)MAG*3*320 install with patch `MAG*3*352' Subject: TELEREADER CONFIGURATOR FONT ISSUE Category: - Routine Description: ============ This document describes MAG*3.0*352, a patch that provides fixes to the VistA Imaging TeleReader Configurator. This patch addresses the following adaptive maintenance item: 1. HDSO-1404 - TeleReader Configurator- On Main screen the font for "Exit" was changed to italicized. Patch Components: ----------------- Files & Fields Associated: File Name (Number) Field Name (Number) New/Modified/Deleted ------------------ ------------------- -------------------- N/A Forms Associated: Form Name File Number New/Modified/Deleted --------- ----------- -------------------- N/A Mail Groups Associated: Mail Group Name New/Modified/Deleted --------------- -------------------- N/A Options Associated: Option Name Type New/Modified/Deleted ----------- ---- -------------------- N/A Protocols Associated: Protocol Name New/Modified/Deleted ------------- -------------------- N/A Security Keys Associated: Security Key Name ----------------- N/A Templates Associated: Template Name Type File Name (Number) New/Modified/Deleted ------------- ---- ------------------ -------------------- N/A Remote Procedures Associated: Remote Procedure Name New/Modified/Deleted --------------------- -------------------- N/A Parameter Definitions Associated: Parameter Name New/Modified/Deleted -------------- -------------------- N/A Additional Information: ----------------------- Blood Bank Team Coordination: N/A New Service Requests (NSRs): N/A Patient Safety Issues (PSIs): N/A Adaptive Maintenance Tracking System Ticket(s) & Overview: -------------------------------------------- 1. HDSO-1404 - TeleReader Configurator- On Main screen the font for "Exit" was changed to italicized. Problem: -------- TeleReader Configurator- On the main screen the font for "Exit" was changed to italicized Resolution: ----------- Modified file "fmagtelereaderadminmain", removing Italic font from the "Exit" button. Test Sites: ----------- VA Central Texas Health Care (Temple, TX) Lebanon VAMC (Lebanon, PA) Software and Documentation Retrieval Instructions: -------------------------------------------------- The software for this patch is being released using a host file. The host file is available at the following location: /srv/vista/patches/SOFTWARE/MAG3_0P352.KID Other Software Files: This release also includes other software files. These files can be obtained by accessing the URL: https://download.vista.domain.ext/index.html/SOFTWARE File Title File Name --------------------------------------------------------------------- Kernel Installation MAG3_0P352.KID and Distribution System (KIDS) build for MAG*3.0*352 TeleReader Configurator MAG3_0P352_TeleReaderConfigurator_Setup.exe client installation file TeleReader Configurator MAG3_0P352_TeleReaderConfigurator_Install.msi push installation file Documentation Title File Name --------------------------------------------------------------------- Patch Description MAG3_0P352_Patch_Description.pdf for MAG*3.0*352 Deployment, Installation, MAG3_0P352_DIBORG.pdf Back-Out, and Rollback Guide Patch Installation: ------------------- Supported Client Versions: -------------------------- When MAG*3.0*352 is released, the list of supported versions of VistA Imaging TeleReader Configurator will change: VistA Imaging TeleReader Configurator Client Versions Supported: -------------------------- 3.0.352 3.0.320 3.0.292 Client Versions No Longer Supported: ------------------------------------ 3.0.281 3.0.242 3.0.219 Pre/Post Installation Overview: ------------------------------- MAG*3.0*352 must be installed on the VistA System and on 64-bit workstations on which the VistA Imaging Applications will be used. This patch must be installed by the compliance date. This patch may be installed with users on the system although it is recommended that it be installed during non-peak hours to minimize potential disruption to users. This patch should take less than 5 minutes to install. Verify that all previous patches have been installed. Note: All released VistA Imaging patches must be installed on the VistA system before installing MAG*3.0*352. Installation Instructions: -------------------------- 1. Use the Load a Distribution option contained on the Kernel Installation and Distribution System Menu to load the Host file. When prompted to "Enter a Host File:" enter /srv/vista/patches/SOFTWARE/MAG3_0P352.KID 2. From the Kernel Installation and Distribution System Menu, select the Installation Menu. From this menu: A. Select the Verify Checksums in Transport Global option to confirm the integrity of the routines that are in the transport global. When prompted for the INSTALL NAME, enter the patch or build name (ex.). NOTE: Using will not bring up a Multi-Package build even if it was loaded immediately before this step. It will only bring up the last patch in the build. B. Select the Backup a Transport Global option to create a backup message. You must use this option and specify what to backup; the entire Build or just Routines. The backup message can be used to restore the routines and components of the build to the pre-patch condition. i. At the Installation option menu, select Backup a Transport Global ii. At the Select INSTALL NAME prompt, enter your build MAG*3*352 iii. When prompted for the following, enter "R" for Routines or "B" for Build. Select one of the following: B Build R Routines Enter response: Build iv. When prompted "Do you wish to secure this message? NO//", press and take the default response of "NO". v. When prompted with, "Send mail to: Last name, First VistA Imaging TeleReader Configurator Client Installation Instructions. Note: The VistA Imaging TeleReader Configurator Application is only supported on Windows 10 operating systems. Other operating systems are not officially supported. VistA Imaging TeleReader Configurator are distributed as an MSI and EXE installation. The MSI is intended for sites that want to do a push installation (using SCCM or another tool). The EXE is intended for use to install on a single workstation. The TeleReader Configurator portion of this patch is to be installed only on the administrator's workstation. The MAG3_0P352_TeleReaderConfigurator_Setup.exe file can be installed manually on workstations as described in the Single Workstation Installation section of the VistA Imaging System Installation Guide. Post-Installation Instructions: ------------------------------- N/A Back-Out/Roll Back Plan: ------------------------ Uninstalling the Application: ----------------------------- If it is necessary to uninstall the MAG*3.0*352 client, use the Uninstall option from Programs and Features within Windows Control Panel to Uninstall: VistA Imaging TeleReader Configurator. Then install the previous version of VistA Imaging TeleReader Configurator which was included in MAG*3.0*320 or refer to the VistA Imaging System Installation Guide on the VA Software Documentation Library at: https://www.domain.ext/vdl/ KIDS Uninstall: ---------------- If it is necessary to uninstall the MAG*3.0*352 VistA KIDS, the patch backup must be installed. The Kernel Installation & Distribution System menu option, Backup a Transport Global should have been used to create a patch backup of the build prior to installing the patch. (see Installation Steps section, step 2b). Administrators will need to check MailMan for the backup message sent by the Backup a Transport Global function executed prior to the patch install. The patch backup must first be loaded from the MailMan backup message, by performing the message action Xtract KIDS, followed by the PackMan function INSTALL/CHECK MESSAGE. The patch may then be installed using the Install Package(s) option in the KIDS Installation menu. 1. Navigate to the Mailman inbox containing the patch backup message. a. Select the MAG*3.0*352 backup message as shown below: * Backup of MAG*3.0*352 install on b. At the "Enter message action:" prompt, select the Xtract PackMan option. c. At the "Select PackMan function:" prompt, select the Install/Check Message option. d. Enter Yes at the prompt "OK to continue with Load?" 2. Navigate to the Kernel Installation and Distribution System Menu and select the Installation Menu. From this menu: a. Select the Install Package(s) option and choose the patch to install. i. If prompted 'Want KIDS to Rebuild Menu Trees Upon Completion of Install? NO//', answer NO. ii. When prompted 'Want KIDS to INHIBIT LOGONs during the install? NO//', answer NO. iii. When prompted 'Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO//', answer NO. iv. When prompted 'Delay Install (Minutes): (0 - 60): 0//', answer 0. Example, Loading Patch Backup (Build) -------------------------------------------- IN Basket Search *=New/!=Priority.........Subject...............Lines.From.....Read/Rcvd 13093. [313643] 09/06/22 Backup of MAG*3.0*352 3099 Search finished. Enter message number or command: 13093 Subj: Backup of MAG*3.0*352 on Sep 06, 2022 [#313643] 09/06/22@12:43 3099 lines From: MANAGER,SYSTEMS In 'IN' basket. Page 1 -------------------------------------------------------------------------- $TXT Created by PROGRAMMER,MAG at DOSO.DOMAIN.EXT (KIDS) on Tuesday, 09/06/22 at 12:42 Warning: Installing this backup patch message will install older versions of routines and Build Components (options, protocols, templates, etc.). Please verify with the Development Team that it is safe to install. Type to continue or '^' to exit: ^ Enter message action (in IN basket): Ignore// Xtract KIDS Select PackMan function: 6 INSTALL/CHECK MESSAGE Line 8 Message #313643 Unloading KIDS Distribution MAG*3.0*352b OK to continue with Load? NO// YES Distribution OK! Want to Continue with Load? YES// Loading Distribution... MAG*3.0*352b Example, Installing Patch Backup (Build) ----------------------------------------------- Select OPTION NAME: XPD MAIN Kernel Installation & Distribution System Select Kernel Installation & Distribution System Option: INstallation Select Installation Option: INstall Package(s) Select INSTALL NAME: MAG*3.0*352b This Distribution was loaded on Sep 07, 2022@11:54:20 with header of Backup of MAG*3.0*352 on Sep 06, 2022 It consisted of the following Install(s): MAG*3.0*352b Checking Install for Package MAG*3.0*352b Install Questions for MAG*3.0*352b Want KIDS to Rebuild Menu Trees Upon Completion of Install? NO// Want KIDS to INHIBIT LOGONs during the install? NO// Want to DISABLE Scheduled Options, Menu Options, and Protocols? NO// Enter the Device you want to print the Install messages. You can queue the install by enter a 'Q' at the device prompt. Enter a '^' to abort the install. DEVICE: HOME// Linux Telnet /SSh MAG*3.0*352b -------------------------------------------------------------------------- Build Distribution Date: Sep 06, 2022 Installing Routines: Sep 07, 2022@11:54:36 Installing PACKAGE COMPONENTS: Installing OPTION Sep 07, 2022@11:54:36 Updating Routine file... Updating KIDS files... MAG*3.0*352b Installed. Sep 07, 2022@11:54:36 NO Install Message sent -------------------------------------------------------------------------- +------------------------------------------------------------+ 100% | 25 50 75 | Complete +------------------------------------------------------------+ Install Completed Routine Information: ==================== The second line of each of these routines now looks like: ;;3.0;IMAGING;**[Patch List]**;Mar 19, 2002;Build 11 The checksums below are new checksums, and can be checked with CHECK1^XTSUMBLD. Routine Name: MAGGTU4T Before: B4926736 After: B4903956 **93,94,106,117,122,127,182, 219,242,281,292,320,352** Routine Name: MAGIP352 Before: n/a After: B4076405 **352** Routine list of preceding patches: 320 ============================================================================= User Information: Entered By : Date Entered : FEB 24, 2023 Completed By: Date Completed: MAY 03, 2023 Released By : Date Released : MAY 04, 2023 ============================================================================= Packman Mail Message: ===================== No routines included