============================================================================= Run Date: MAR 04, 2005 Designation: MAG*3*48 Package : MAG - IMAGING Priority: Mandatory Version : 3 SEQ #29 Status: Released Compliance Date: MAR 31, 2005 ============================================================================= Associated patches: (v)MAG*3*8 <<= must be installed BEFORE `MAG*3*48' Subject: Clinical Capture and Display Maintenance Category: - Routine Description: ============ VistA Imaging Clinical Document Imaging patch, MAG*3.0*48, is a follow up to patch MAG*3*8. It includes major enhancements to Clinical Capture and Display, enhancements and fixes to the Background Processor, and on-line help for the Diagram Annotation window. Major changes are outlined below. Patch 48 contains the following new functions and features: - There is a new option on the tools menu in Display that allows the user to reopen the Cine View window if it should get closed. - The Cine Control window can no longer be adjusted according to size. - The maximum number of frames in a selected image is now displayed in the Cine View window. - In Display DOD and FEE check boxes were added to the choices for Origin on Image Filter window. - In Capture DOD and FEE were added to Origin field list of values. - The type index terms, OUTSIDE MEDICAL RECORD (FEE AND DOD) are no longer available. These are replaced with the type index MEDICAL RECORD modified by an Origin Index selection. - Sites can enable or disable version checking for Clinical Display and Capture by setting a new field in the IMAGING SITE PARAMETERS file (#2006.1). - Support staff may modify the number of days that full images are kept on RAID storage. - Auto-purge - new feature that automatically starts and stops the purge process without user intervention. - The magnifying glass tool now defaults to the magnify option in the Radiology window. - The Private and Public Filters lists in the Image Filter Add/Edit window now displays a "delete" option in the popup menu. - New functions have been added to the Image Delete window. The functions give the user the option of displaying details associated with the Image or Image Group. Also, abstracts and reports can be viewed for images that have Questionable Integrity issues. - Image Groups can now be deleted from the Imaging Display GUI. Users must have the security keys MAG DELETE and MAG SYSTEM. The 'Image Group Delete' menu option will not be visible for users that do not have the required keys. - Added '5 years' as a new filter date selection in the Filter Edit window "Date Range" dropdown list. - The Release of Information (ROI) support staff will now be able to utilize the following new reason "Authorized Release of Medical Records or Health Information (ROI )" added to the lists of reasons for Print/Copy. Patch 48 corrects problems so that: - The Radiology viewer will not display FullRes images that have an odd number of columns in the image header information. - In DICOM images, the user is now able to adjust the brightness and contrast of color with a right-mouse drag. - The patient's name now appears in the Image Information Advanced window. - Scroll bars no longer disappear when viewing a multi-page document in the FullRes viewer. - The full path and filenames of imported images can now contain more than one period in the file name and greater than three characters for a file extension. - Capture Import function no longer displays an error message when the image filename is greater than 80 characters long. - The patient's name and SSN are displayed on all printed images. - When editing the "Package" parameter on a Filter, users can now select an entry that is less than three characters, e.g. "CP". - Duplicate Import queue entries are only processed once, but are only re-queued twice when the process is failed. - Printing multi-page images will now require a single electronic signature. - When selecting an Import Directory, the filename in the Import Directory dialog window defaults to "all files". - Defaults are set correctly for paging in Stack Mode for Clinical Display client Radiology Viewer. - Diagram Annotation will now display the on-line help file correctly. - Background Processor log files are no longer automatically purged. They are now placed in their own "LOG" subfolder descending from the application subfolder. - The SCHEDULED PURGE TIME field (field# 64 in file #2006.1) will now accept 3 or 4 digits in 24 hour inputs. - The Jukebox share no longer displays in the action column with the Queue processor display window. - "Wrong case/exam/accession number" has been added to the list of "Reasons for deletion" in the Image Delete Window. - All images that have Questionable Integrity issues are now allowed to be deleted. The Image abstract, Report and Information can be displayed in the Image Delete window for verification. - The Display and Capture Clients now display site information for both consolidated and non-consolidated sites. - The toolbar in the Full Resolution viewer will now wrap to multiple lines if the entire toolbar cannot be displayed at once. - The Radiology Exam listing window will now have columns sized to fit text. - Orientation markers for CT studies no longer show a distorted view of the Right orientation marker "R", users can still view images and markers in a configuration that does not allow much screen space. - The Radiology Window images will now allow the caption to include the case number of one or two studies. The case number is included in each individual stack and a hint is now viewable when mouse stays near the caption beneath each individual image. - Images that were incorrectly exported to an Imaging magnetic drive, instead of being copied to the Health Eligibility Center (HEC) share will now be correctly exported to the designated HEC share. - The report button in the FullRes window now displays a "confirmation message" if the user has not loaded or selected images. - Changing associations in the Capture window no longer generates an "access violation". - In the Patient Lookup window, the "OK" button will now be disabled when the list is empty. - In Capture, users will no longer be able to save a "Configuration List" without a name. - Sites can now run the Verifier over an IEN range to create Abstracts for images of TIF extensions. - In the Capture window, the information displayed above a scanned document will now contain the correct format of the Image. - Clicking the Report button for images that have been deleted will no longer generate an error. - Scheduled purges will now activate on time when the scheduled purge parameters are properly configured. - Users will no longer receive "access violation" messages in various sequences when using the EDIT|Add/Remove BP Workstation menu from the BP Queue Processor Main window. - Editing the Routing fields on the Background Processor client software via the Network Location Manger menu will now update the database. - Auto-Purge parameters will now restore only the field value in error. - The creation of new log files in the Background Processor will no longer give the user an "access violation" message. The data column headers were also removed from the log files. - In the FullRes Viewer the tool buttons were reorganized to have the "Close Selected" and "Close All" buttons as the last two on the first row when the toolbar wraps into two rows. - Field Unit Test 51 is included in Patch 48. Field Unit Test 51 corrected the error that occurred during the capture process when verifying the value of the Institution. The error would disable the ability to capture Lab Images from the Capture Workstation. - The Online help for the Delete window is now the correct file. - The Configuration buttons in Capture will now resize automatically to fit the button title. Buttons will wrap into as many rows needed or display scroll buttons to the right of toolbar if there are more buttons than can fit in a single row. - Future dates will no longer be allowed for both the "Study Date" and "Document Date" fields. - In the FullRes Viewer defaults for new users are now changed to: 1 row by 1 column and the fit method for images now default to "Fit to Width". The Fit method will be saved in "User Preferences". - The design for printing and copying multi-page images now only requires a single electronic signature. - Users with MAG ROI security key will no longer be required to enter an electronic signature. - Keystrokes for Print/Copy functions have been drastically reduced. - Site Managers can now delete Public Folders from the GUI. - Abstracts of a previous patient no longer stay visible in the "Preview Abstracts" panel of the Image List window, when a new patient is selected that has no images. - Viewing PDF files will not display an Error Dialog incorrectly. - DCM Grayscale Images will now display correctly in the Radiology Viewer. - Scrollbar labels will now load 16-bit grayscale images into the Radiology window. - Annotation callback code was revised to only send an error message when the status is "Error". - Sites that are running VistA Imaging on Thin Clients will no longer experience the error message "Exception: I/O error 32" when the VistA Application is started. NOTE: Do not install this patch if your site is a test site for VistA Imaging v2.5 consolidation software. Detailed patch information and installation instructions can be found in the MAG3_0P48 Patch Description. Any late-breaking information will be documented in a readme file. Documentation will also be posted at http:/vaww.va.gov/Imaging/3.0patches.htm shortly after this patch is released. There may be a brief delay between the distribution of this message and the availability of the patch at the FTP site. This patch can be downloaded from: ================================= ftp.imaging.med.va.gov/Software/Released_Software/Mag3_0P48 FDA regulations require that each Imaging software distribution is documented and tracked by the VistA Imaging project. To receive this patch, sites must have a Site Agreement filed with and approved by the VistA Imaging Group. For information about the status of a Site Agreement, contact the VistA Imaging Distribution Manager via phone (301-734-0357) or email (Kathy.Trombetta@med.va.gov). Patch Contents: ============== This patch includes the following software: ReadMe.txt - Late breaking news on Auto updating and remote pushes using PSExec. Please read this file first. MAG30P48.KID - KIDS (Kernel Installation & Distribution System) package to be installed on the VistA hospital database. MagBPSetup.exe - Installation file for Background Processor client software. MagInstall.exe - Installation file for Clinical Display and Capture client software. MagInstall.msi - Installation file for sites using SMS or similar software. MagAUShare.zip - Files required for Autoupdate (see MAG3_0P48_G2_5_5_Auto_Update.pdf for installation instructions) Documentation: MAG3_0P48_Patch_Desc.pdf - Patch 48's description and installation instructions. MAG3_0P48_IMGtechmanSec10_2_3_1InputArray.pdf - Technical Manual change pages with updated Input Array sent to Import API notes. MAG3_0P48_IMGtechmanSec10_2_3_3ResultsArray.pdf - Technical Manual change pages with updated Results Array returned to Status Handler notes. MAG3_0P48_IMGtechmanSec11_1_2DeleteImg.pdf - Technical Manual change pages with updated deleting images and pointers notes. MAG3_0P48_IMGtechmanSec3_6Securitykeys.df - Technical Manual change pages with updated security keys. MAG3_0P48_IMGtechmanSec6_1_1Checksums.pdf - Technical Manual change pages with updated checksums. MAG3_0P48_IMGtechmanSec6_4_1ClinWrkStatFiles.pdf - Technical Manual change pages with updated list of Clinical Workstation files. MAG3_0P48_IMGtechmanSec6_4_2BProcFiles.pdf - Technical Manual change pages with updated list of Background Processor files. MAG3_0P48_IMGtechmanSec7_2_4FurInfo.pdf - Technical Manual change pages with updated Section Name notes. MAG3_0P48_IMGinstallgdSec2_5_6_3WrkstatConfigFileSet.pdf - Installation Guide change pages with updated Workstation Configuration file settings. MAG3_0P48_IMGinstallgdSec2_7_3_3ConfigCapWrkStatMeansTestFileSet.pdf - Installation Guide with updated Capture workstation configuration for Means Test scanning. NOIS Entries: ============= All NOIS (National Online Information System) calls addressed in this patch are: HUN-0102-20713 WIM-0904-21594 PRO-1004-10056 PRO-1004-10359 ALB-1104-50145 MAC-1104-60297 CMS-1004-30585 PRO-1104-10883 RIC-1104-20847 WRJ-1104-11507 CON-1204-10065 CON-1204-10066 ASH-0804-31332 WBP-0704-20842 LOU-1204-41351 TUC-1104-61304 E3R Entries ========= The following E3R (Electronic Error and Enhancement Reporting Package) entry is addressed in the MAG3_0P48. 19095 Test Sites: =========== This patch was tested at the following sites: El Paso, TX Fayetteville, NC Loma Linda, CA Grand Junction, CO New Mexico Puget Sound, WA Routine Information: ==================== ============================================================================= User Information: Entered By : CASUGAY,ELSIE G Date Entered : NOV 04, 2004 Completed By: BARRIOS,LUCILLE Date Completed: MAR 03, 2005 Released By : LOVING,MANLEY Date Released : MAR 04, 2005 ============================================================================= Packman Mail Message: ===================== No routines included