============================================================================= Run Date: AUG 11, 2003 Designation: OR*3*149 Package : OR - ORDER ENTRY/RESULTS REPORTING Priority: Mandatory Version : 3 SEQ #171 Status: Released Compliance Date: SEP 11, 2003 ============================================================================= Associated patches: (v)OR*3*141 <<= must be installed BEFORE `OR*3*149' (v)OR*3*158 <<= must be installed BEFORE `OR*3*149' (v)XU*8*267 <<= must be installed BEFORE `OR*3*149' (v)GMRC*3*29 <<= must be installed BEFORE `OR*3*149' (v)OR*3*163 <<= must be installed BEFORE `OR*3*149' (v)OR*3*165 <<= must be installed BEFORE `OR*3*149' Subject: CPRS GUI version 21 Category: - Enhancement (Mandatory) - Routine - Other Description: ============ PATCH DESCRIPTION: ================= Patch OR*3*149 implements Section 508 functionality. Numerous other enhancements and fixes, noted below, are also included. -- ALL SCREENS - Different Windows color schemes are supported. All CPRS screens now reflect the color scheme in use. Cream color for read-only data is only used when font color in scheme is black. Otherwise, read-only data is unmarked or appears in tooltip hint colors. The black-on-black and white-on-white problems that appeared under non-standard Windows color schemes are fixed. - Editing fields that accept tabs (such as the new note field) can now be exited through the keyboard: keystroke will move focus to the next item in the tab sequence; , and keystrokes will move focus to the previous item. - Forms that contain tabbed sheets allow the navigation of these tabs using and , provided that the focus is not in an editing field that accepts tabs. - Active Accessibility changes have been made to many screens. CPRS should work well enough with common screen readers (text-to-voice) that navigation is possible without cues from the screen. Navigation is also possible using common voice-to-text software. - Font sizes are now applied to all screens. Font changes will generally resize screen components to fit the font. Some Order screens that retain their saved preferences do not get resized. You will have to manually resize these screens once, and then CPRS will remember the new screen dimensions in following sessions. NOTE: CPRS does not change the system font sizes, which are used in menus and alert boxes. The user that wants consistency will need to go into the desktop options and change or modify his Windows color scheme. - The tab sequence (the order that controls are activated by using the tab key to navigate through them) has been cleaned up. Tab order generally proceeds from left to right and from top to bottom. Speed buttons, as well as open or closed drawers are now included in the tab sequence. Hidden controls are not included in the tab sequence. HTML pages do not respond to focus, so are not included in the tab sequence. - NOIS: SHR-1099-72902 - Font sizes are now saved between sessions. -- COM OBJECT REGISTRATION DURING INSTALLATION - Section 508 changes necessitated inclusion of some COM objects in CPRS. During installation, registration of these objects was restricted due to a bug in Delphi's COM object registration code. This was corrected and registration should proceed without problems now. However, a Poweruser or Administrator user will still need to run the application one time following installation on any workstation where a disabled user will wish to utilize applications which access the COM objects while using CPRS GUI. -- PATIENT SELECTION SCREEN - Pressing while in the patient list toggles the display of patient demographics from the current display to a display inside a memo field where text is highlighted. This feature lets text-to-voice software quickly read patient demographic information when needed. - NOIS: PUG-0400-50702 - When viewing Wards, name column has room for longer names before Room/Bed column. Also fixed bug where when Default View is Wards, the Room/Bed was not showing up. - NOIS: SHE-0701-51513 - When selecting a patient from a Ward, the short list would disappear. This has been fixed. - NOIS: CHA-0499-31537 - When all patients displayed, the short list (containing the last patient seen) is only shown on startup. -- LOCATION SELECTION - NOIS: LEX-0300-43110, LEX-0902-41608 - Location selection in the GUI was not consistent with LM location selection. "Other" type hospital locations were not included. This has been changed to improve the GUI selection functionality and to make it consistent with LM practices. -- DRAWERS - A user can now open or close reminder and template drawers by pressing the space bar when the drawer is selected. - NOIS: ISH-1001-42951 - Added shortcuts to pop-up menu in templates drawer: Copy Template Text: Ctrl+C Preview/Print Template: Ctrl+W Goto Default: Ctrl+G Mark as Default: Ctrl+Space Find Templates: Ctrl+F Insert Template: Ctrl+Ins View Template Notes: Ctrl+V -- REPORTS - When the "Clinical Reports\Radiology\Imaging (local only)" branch is selected a new treeview will display in the lower left corner containing a hierarchical view of the parent and descendant procedures. If a stand-alone procedure is selected, the report will be displayed and a new label above the procedures listview will indicate "Standalone - single procedure". If a parent procedure is selected for which all descendents share a report, the report will be displayed and the new label above the procedure listview will indicate "Descendent Procedures with shared report". If a parent procedure is selected for which all descendents have individual reports, the report will not be displayed and the new label above the procedure listview will indicate "Descendent Procedures - Select to view individual reports". If a descendent procedure is selected the associated report will be displayed. - As a side effect of the above changes, a problem reported in WRJ-1202-50989, related to raw Mumps data being displayed, was also corrected. - A user can now view a selected report by pressing the space bar. - NOIS JAC-0103-70775: Fixed problem that was created in v20 of the GUI that was keeping Medicine Procedures from printing to a DHCP printer. - E3R: #17541, NOIS: HUN-1002-20538 - A new column was added to the "Imaging (local only)" reports list to reflect "Exam Status". This will be displayed in addition to "Report Status", and will help clarify the meaning of "No Report" appearing in that existing column. - Sites have reported long delays when selecting remote sites after clicking on the Blue Remote Data Views button, while CPRS tries to do a direct connect with the selected remote sites to check for connectivity, remote procedure compatibility and sensitive patient information. These checks have been disabled in this version, which will speed up the process of getting remote data. Any failed remote queries will continue to show in the list of remote sites when clicking on the Blue remote data button. Related NOIS: SHE-0203-51549 MAD-0103-42062 POR-0103-51518 HAM-0103-22079 CPH-0802-41376 -- NOTES/CONSULTS/DISCHARGE SUMMARY/SURGERY - Shortcuts were added, similar to default key strokes, to the Action Menu: New Progress Note...: Shift+Ctrl+N (CONSULTS - Complete/Update Results : Shift+Ctrl+U) Make Addendum...: Shift+Ctrl+M Change Title...: Shift+Ctrl+C Delete Progress Note...: Shift+Ctrl+D Edit Progress Note...: Shift+Ctrl+E Save without Signature: Shift+Ctrl+A Sign Note Now...: Shift+Ctrl+G - To remove conflicting shortcuts, the "Reformat" shortcut has been changed from CTRL-R to SHIFT-CTRL-R. Similarly, the "Save and Continue" shortcut was changed from CTRL-S to SHIFT-CTRL-S. Additionally, new items have been added to the popup menu in the editing field: Preview/Print Current Template: Ctrl-W Insert Current Template: Ctrl-Ins Edit Encounter Information: Ctrl-E - (Text-to-voice software): The note tree views alter the text they supply to text-to-voice software to aid navigation. The text begins where it differs from the previous entry, and the common text is included in parentheses at the end. For instance, if the items in the tree view were: Oct 01,02 ID CHILD BARRY, 1A(1&2), GARY EGLI Oct 01,02 ID CHILD AMY, 1A(1&2), GARY EGLI then the text-to-voice software would voice the second line as: AMY, 1A(1&2), GARY EGLI (Oct 01,02 ID CHILD) This "short name" functionality only affects accessibility software. - NOIS: FNC-0302-32025 - Fixed Access Violation when creating new note while JAWS text-to-voice software is being used. - NOIS: PUG-0599-50862, WIC-1000-42228, MAC-0401-61264 - When beginning a new TIU document with no current visit defined, the user is required to select a visit before continuing. In this scenario, the "New Visit" tab of the visit selection form did not previously respect the user's TIU personal preference for default location. This has been corrected. - NOIS: CHY-0802-51098, SLC-0702-51512, NHM-0802-11099, LAS-0802-61291, DUB-0802-32068, TUA-0902-31341, MAN-0902-11354, ERI-1102-20210, MAR-1102-20666, SAG-0902-41964, SAM-1102-21519, BEC-1102-21756, GRJ-1102-52199 - Added code to disable the auto-save timer while a save is currently in progress. This should prevent the auto-save error reported in numerous NOIS calls. - Added similar code to the spell and grammar check menu items on all tabs, so that an auto-save should not begin while a spell or grammar check is in progress. This may or may not have been a contributing factor to earlier spell/checker problems, but should reduce the possibility of problems in any case. - If a date range view of notes was selected with TODAY as the end date, notes entered today were displayed in the treeview, but not in the upper right-hand listview. This has been corrected. (COA-1202-21927) - The edit width for progress notes is now limited to 74 characters. The vertical scrollbar should no longer disappear. This applies to the Notes, Consults, D/C Summary and Surgery tabs. (SDC-0801-61318, CLA-1201-21047, BAY-0302-30627, HON-0302-61446, MAR-0302-21736, PRO-0502-12122, MAC-0602-62654, MIA-0602-33096, SLC-0702-52378, TUA-1102-32011, PRE-0103-61732) -- PROGRESS NOTE PROPERTIES - The note title combo box now provides "short name" functionality for text-to-voice software. See entry in NOTES/CONSULTS/DISCHARGE SUMMARY/SURGERY for detailed description. - On the Note Properties dialog, selecting a consults title no longer deselects a previously-selected consult. -- CONSULTS - E3R# 16981 - When beginning a new note from the Notes tab, a check is now made to determine whether the current user has any unresolved consults that he/she may wish to address. If any are found, a short message to that effect is displayed, and asks if the user would like to display a list of these consults. Clicking "YES" will display the note title selection screen with unresolved consults listed below. Clicking "IGNORE" will proceed to the same title selection screen as if writing a progress note, and not display the consults. Whether or not the message is displayed is controlled by a new parameter ORWOR SHOW CONSULTS, which can be set by PACKAGE, SYSTEM, DIVISION, or USER. The exported PACKAGE value is to display the message. (This E3R has been endorsed by HIMS as a Medical Records issue with the ever-growing list of incomplete consults.) - E3R#'s 13654, 17381, NOIS: LON-0701-62384 - For the "Add Comment", "Schedule", and "Significant Findings" actions, the selection of alert recipients has been modified. If the user is not the ordering provider, then the ordering provider will automatically be sent an alert. If the user is not an update user for the receiving service, then all update users for that service will now automatically be alerted. If the user fits neither of those categories, then both the ordering provider and the receiving service's update users will automatically be alerted. A statement will appear above the alert checkbox telling the user who will automatically receive alerts. The user can also send additional alerts by the same method currently available for those actions. Automatic alert recipients will not appear in the selected recipients list if additional alert recipients are being designated, and will receive alerts without being manually added to that list. - NOIS: PUG-0403-51270 - The "Services Rendered As" entry of Inpatient or Outpatient was sometimes not being passed correctly to the order, even though correctly checked on the form. This has been corrected. - Corrected a problem where processing an alert that led to the Consults tab was producing the error message "Cannot focus a disabled or invisible window." - Corrected a problem where, if editing a note on the Consults tab and then changing to a different tab while editing, the note disappeared from the Consults tab. It was saved and still visible from the Notes tab, but possibly no longer linked to the selected consult. - Corrected a forwarding issue related to procedures only. Not all available services who could receive that type of procedure were selectable. -- TEMPLATES - CHECKBOX FOCUS AND CAPTIONS: Parent checkboxes on templates and subtemplates now display a standard Windows focus rectangle when they have focus. This is achieved without adding any additional text lines to templates to accommodate an associated checkbox caption. Each parent checkbox has an associated caption that is readable by screen-readers, but which is not visible on the template display. A screen-reader user is therefore, able to navigate around the screen and hear the captions that are associated with parent checkboxes, but those same captions are not visible on the template display, thereby preserving the original "look and feel" of the templates. - When a COM object is assigned to a TIU title via a template, and that COM object is executed by selection of that title, the TIU document IEN in file 8925 is now passed in the COM object's "Data2" parameter in XML format, as follows, where 'nnnnn' is the document IEN. Author information is also passed in Data2, as shown, where AUTHOR_IEN contains a pointer to the author's entry in the NEW PERSON file: nnnnn nnnnn last,first - If that same COM object returns a change of author, in the same format shown, the CPRS Notes tab will validate that author, determine any cosignature requirements, and if possible, update the current note with the new author information. The other TIU tabs (Consults, Surgery, Discharge Summary) do not yet support this change-of-author functionality, because of other complicating factors related to who may be the author of a document on those tabs. - E3R# 17150 - The original documentation outlining COM object interfacing to CPRS has been updated to reflect this new functionality. -- ENCOUNTER FORM - NOIS: MAC-0501-61136, MAC-0201-61795, SLC-0801-52086 - It is now a requirement to enter a provider responsible for each new procedure entered on the PROCEDURES tab. Existing procedures on existing encounters are not retroactively requiring this information. One result of this change should be that editing of CPT information in PCE via the CPRS encounter form should now work correctly. - NOIS: FAR-0102-42056, POR-0502-52623 - If two patients were booked for the same date/time and location, via an overbook or a group visit, selecting the encounter form for a second patient in this group would result in the first patient's encounter form selections being pre-stuffed for that subsequent patient. This incorrect data existed only on the client, and was not yet saved, but could result in acceptance of incorrect encounter information for those subsequent patients. This has been corrected. - The list of providers selectable on the Procedures tab was not derived by the same method as the list of providers on the Visit Type tab. Now, instead of the procedure provider screening on the PROVIDER key, a valid person class in file 200 as of the encounter date is required, as has been the case on the Visit Type tab. The exception on both tabs is for event historical visits, where the entire NEW PERSON file remains selectable as before. - There will now be a default entry for the provider on the Procedures tab for each procedure/CPT code entered. In order of precedence/availability, this default will be either the currently selected encounter provider as shown on the toolbar, the current user, or the currently designated primary encounter provider. If none of these can be selected as the provider, then no default will be preset. -- COVER SHEET - The patient info box no longer has a light blue background. Instead, the patient info box uses the tool tip colors to appear as read-only text. - When a user uses the tab key to navigate through fields, the focus stays on the active tab. - NOIS: SDC-0102-61412 - Panel dimensions are now saved between sessions. - NOIS: WPB-0298-30483 - The Provider Name is now displayed in correct mixed-case format. - A bug was causing the bottom row of lists to not resize when the bottom splitter was moved, which created a lot of empty space on form. This has been fixed. This also fixed other strange sizing bugs in v21.6. -- OPTIONS - Rapid clicking on unfocused check boxes no longer causes focused checkbox to change. -- EVENT DELAYED ORDERS - NOIS: HIN-0103-40640,MAD-1202-41810,CHA-0103-30592: When placing a medication quick order for a delayed admission event, users received the error "This drug may not be ordered for an outpatient". This has been fixed. -- ORDERS - Unsigned orders are now underlined. Unsigned orders for the current provider are now bold and underlined. - Flagged orders now have a tag reading "*Flagged*" added to the end of the order field, in much the same way that unsigned orders are marked "*Unsigned*". - Right-clicking on an unselected order will show the popup menu and select the order. - The Order Check list displayed after Accepting an order now has scroll bars if multiple order check messages exist. - Blue and Red highlighting is disabled when running under incompatible Windows color schemes. - The message box that pops up in the order screens now acts a little differently. It does not disappear as quickly, so that it is accessible to text-to-speech utilities. Clicking on text does not make it disappear, but clicking on info glyph does. Additionally, code has been added to let the user drag the message box to a different position on the forms. - NOIS WAS-0103-20776: In CPRS, the opened med order dialog automatically closed when switching tabs between Orders and Meds. This has been fixed. - NOIS MWV-0702-20284, MIW-0702-42956: Patient Safety Issue - When processing an outpatient med order, when a pharmacist copied the provider comment to Patient Instruction (PI), then later if a clinician tried to change this order to a different dosage or schedule, the original provider comment appeared in the PI label and could not be edited. Also, for a long PI the patient instruction text couldn't be fully displayed in the med order dialog. These have been fixed. - NOIS PHO-0103-60618: Users were unable to copy a inpatient medication order to outpatient on delayed discharge event. This was fixed. - NOIS WAS-0103-20776: Users could not switch between Meds and Orders tab with an opened order dialog. This was fixed. - NOIS FAR-0103-40836: For the delayed admit order on an outpatient, the active event default order didn't get printed. This was fixed. - A vertical splitter has been added above New Orders button to allow resizing of the orders list column. - NOIS: PRE-0201-61808, BAC-0501-41554 - When verifying changed orders, the replaced orders were not being auto-verified as intended; in GUI the replaced orders were not auto-verified at all, and in List Manager only the first replaced order (if there were more than one) would be auto-verified. If the verification was done via Pharmacy package options for med orders, the order was not being updated if the replaced order had already been verified. Items fixed. - In the inpatient medication order dialog, the "First Dose Now" check box caused some confusion among clinicians. It has been changed to "Give additional dose now." -- CUSTOM ORDER MENU - To avoid color coding, visited menu items are underlined. Whatever made menu items underlined now makes then bolded. -- INPATIENT/OUTPATIENT MEDICATION ORDERS - In the Complex Meds grid, the user can now bring up the field editors by pressing the enter key. The user can insert a row by pressing the insert key. The user can delete the currently selected row by pressing delete. The user can drop down the list on the "then/and" editor by pressing space. - In the Complex Meds grid, the user is now prevented from entering a new dosage into a row unless the previous row has a dosage. This complements an existing behavior where the user is prevented from entering other data on a row without a dosage. Note that gaps can still occur if the user presses the "Insert Row" button. - By maximizing the Medication Orders screen and selecting a non-formulary drug, the user could bring up an inaccessible alert box. Focus then could not be returned to the program. This has been fixed. - NOIS: CPH-0902-40822 - By using tab key to navigate each box for placing a complex outpatient med order, the quantity could not be calculated correctly. This has been fixed. - NOIS: UNY-0702-11996 - For a lab order which was previously accepted by LES (Lab Expert System), if modified and the modified order was deleted by LES, the order was still added to the order sheet in CPRS because of lack of communication between CPRS and LES for processing modified lab orders. This has been fixed. - NOIS: JAC-0602-72390 - for some IV orders on an outpatient, the DEA check logic was incorrect and presented a DEA requirement message even though the orderable item should not have required a DEA check. This was fixed. - For Inpatient Complex Orders the Change action was not allowed for any child orders of a complex order. For Discontinue/Hold/Release Hold/Verify, all or none of the child orders of a complex order had to be selected in order to take action. The renew action is only allowed on a complex order with the "AND" conjunction. A complex order with the "THEN" conjunction now cannot be renewed. -- LAB ORDERS - A user can now navigate the calendar in the "future" order popup using and /. - NOIS: ALB-0700-50831 - Added right-click menu to lab order message box to allow user to view complex lab messages in a report box. -- PROCEDURE ORDERS - NOIS: BAY-0402-32054, HOU-0802-71657 - Corrected reported issue where Provisional Diagnosis value and prompting requirements were carrying over not only between quick orders, but also between successive patients. - "List Index Out of Bounds(-1)" error that occurred when an inactive orderable item was included in a procedure quick order was corrected. The generic Procedures order dialog will now be displayed in that situation. (From V20 patch tracker.) -- DIET ORDERS - A new radio button named has been added to the Meals group. This is selected by default, and preserves all behavior that would occur in earlier versions if no meal were selected. -- ALLERGY ORDERING - NOIS: SBY-0901-30661 - A patient safety issue was reported has been corrected. In certain circumstances. The REACTION TYPE was not being passed from the client to the server when the ACCEPT button was clicked, resulting in an allergy/adverse reaction that was missing this piece of information. The situation also caused a server error at ALG+6^ORMBLDAL, which was also corrected. -- SPELLING AND GRAMMAR CHECKING - NOIS: HUN-0802-20049, MIN-0802-40944, HIN-0802-41251, DET-0802-41296 - A patient safety issue was reported in v19.15 which resulted in the disabling of spelling and grammar checking in an emergency v19.16. Users were reporting that some or all of the text of the document being checked was disappearing on returning from the spelling or grammar check. Portions of notes were being lost in this manner. This version re-enables the spelling and grammar checking functionality. A separate document has been provided outlining which issues have definitely been addressed and which more minor issues could not be addressed due to limitations of Delphi, Microsoft Word, or Windows itself. - Although spell-checking issues are believed to be corrected, the absolute correct behavior of this functionality may be very workstation-specific, or even user-specific. To provide a means of control of this functionality at the site level in the event that further problems are encountered, a new parameter has been added, "ORWOR SPELL CHECK ENABLED?", which can be set at the PACKAGE, SYSTEM, and USER levels via the XPAR MENU TOOLS options. This parameter now controls the availability of both spelling and grammar checking in the GUI. The exported PACKAGE value with this patch is ENABLED. - NOIS: PUG-1001-52969 - A hover hint was added to the Consults title and Discharge Summary title. Thus if the screen is unable to display the entire title, hovering the cursor over it will cause a full display. - Corrected a problem noted at some sites where text returned to the note by the spell-checker was being wrapped inappropriately. -- STARTUP - CPRS GUI determines client and server versions, then decides whether compatibility exists determined by various factors or settings. If a bad entry existed in the OR CPRS GUI CHART menu option, the GUI could start with no error message but functioning improperly. This bug has been addressed. - NOIS: UNY-0302-10994 - CPRS supports a "SPLASH=OFF" command-line parameter that will disable the splash screen during startup. -- VISIT SELECTION SCREEN - NOIS: HWH-1102-42068, MAC-0702-61207 - An intermittent access violation related to display of a hover hint was reported. This was corrected. -- CLINICAL REMINDERS - NOIS DET-1002-40094: Fixed duplicate Captions for Primary Diagnosis, Add to Problem List, and CONTRAINDICATED Prompt. - Spacing in the reminders dialog was restored to v20 behavior. REQUIRED BUILDS: =============== GMRC*3.0*29 OR*3.0*141 OR*3.0*158 OR*3.0*163 OR*3.0*165 XU*8.0*267 "Informational Patch" OR*3*126 (released) will need to be applied to any machines using JAWS to make CPRS fully accessible in that environment. NOTE: Internet Explorer 4.0 (IE4) or later is REQUIRED in order for GUI version 21 to run. However IE 5.5 or later with 128-bit required for PKI functionality. ROUTINE SUMMARY: =============== The following is a list of the routine(s) included in this patch. The second line of each of these routine(s) will look like: ;;3.0;ORDER ENTRY/RESULTS REPORTING;**[patch list]**;Dec 17, 1997 CHECK^XTSUMBLD results Routine name Before Patch After Patch Patch List ============ ============ =========== ========== ORCACT1 9905918 11556603 7,27,56,48,86,92,116,149 ORCACT2 19116395 20356550 7,48,79,92,108,94,141,149 ORCACT4 16585010 18580609 7,27,116,141,149 ORCDPS1 20120501 20585225 94,117,141,149 ORCDPS3 11604082 11651346 94,116,134,158,149 ORCSEND1 18325578 18906819 4,29,45,61,79,94,116,138, 158,149 ORECS01 455464 1246495 141,149 OREVNTX1 7617262 7653456 141,165,149 ORMPS 18029252 18311599 3,54,62,86,92,94,116,138, 152,141,165,149 ORMPS1 17505514 17984587 86,92,94,116,134,152,158, 149 ORQQCN2 6430061 6417290 10,85,125,131,149 ORWCH 4891285 4998621 10,109,149 ORWDPS5 N/A 1208555 149 ORWDXA 14250322 16360538 10,85,116,132,148,141,149 ORWDXR 7320725 8455080 10,85,125,131,134,141,149 ORWPT 10350226 10288591 10,85,149 ORWRA 2173019 2875856 10,85,109,135,132,148,154, 141,149 ORWTPN 5335659 8146714 85,149 ORWTPP 2017330 2096645 85,149 ORWU 12875509 12885276 10,85,132,148,149 ORWU1 N/A 6108880 149 ORY149 N/A 2316897 149 DATA GLOBALS: ============ The following files will be updated or modified by this patch: OE/RR REPORT PARAMETER DEFINITION INSTALLATION FILES: ================== Inasmuch as this patch is installed as one patch in a multi-patch distribution, no individual installation files exist for OR*3*149. Please see Patch OR*3*173 for information on the multi-patch installation files that will install this patch. INSTALLATION INSTRUCTIONS: ========================= Section 508 Note: For disabled users the client side executable program will need to be initially run one time by a user logged in as Administrator; this is required for third party programs such as "JAWS" or "WindowEyes" to properly create COM registry entries. Following this initial startup, the program should subsequently operate with the provided 508 functionality on that workstation for non-Administrator logins. This patch will be installed as part of a multi-package install. For actual installation instructions, see the INSTALLATION INSTRUCTIONS from Patch OR*3.0*173. Routine Information: ==================== Routine Name: - ORWPT Routine Checksum: Routine Name: - ORWU Routine Checksum: Routine Name: - ORWU1 Routine Checksum: Routine Name: - ORCACT1 Routine Checksum: Routine Name: - ORCACT2 Routine Checksum: Routine Name: - ORCACT4 Routine Checksum: Routine Name: - ORCSEND1 Routine Checksum: Routine Name: - ORQQCN2 Routine Checksum: Routine Name: - ORWCH Routine Checksum: Routine Name: - ORWDPS5 Routine Checksum: Routine Name: - ORWDXA Routine Checksum: Routine Name: - ORWDXR Routine Checksum: Routine Name: - ORWTPP Routine Checksum: Routine Name: - ORWTPN Routine Checksum: Routine Name: - ORY149 Routine Checksum: Routine Name: - ORWRA Routine Checksum: Routine Name: - ORMPS1 Routine Checksum: Routine Name: - ORCDPS1 Routine Checksum: Routine Name: - OREVNTX1 Routine Checksum: Routine Name: - ORECS01 Routine Checksum: Routine Name: - ORCDPS3 Routine Checksum: Routine Name: - ORMPS Routine Checksum: ============================================================================= User Information: Entered By : SHARP,PAUL Date Entered : JUN 10, 2002 Completed By: INSLEY,MARCIA Date Completed: AUG 11, 2003 Released By : STRONG,NICK Date Released : AUG 11, 2003 ============================================================================= Packman Mail Message: ===================== No routines included