$TXT Created by SMITH,ROBERT at MNTVBB.FO-ALBANY.MED.VA.GOV (KIDS) on Wednesday, 01/07/04 at 11:52 ============================================================================= Run Date: MAR 04, 2004 Designation: SR*3*122 Package : SR - SURGERY Priority: Mandatory Version : 3 SEQ #119 Status: Released Compliance Date: APR 04, 2004 ============================================================================= Associated patches: (v)SR*3*41 <<= must be installed BEFORE `SR*3*122' (v)SR*3*80 <<= must be installed BEFORE `SR*3*122' Subject: SURGERY INTERFACE PARAMETER FILES OUTDATED Category: - Other - Routine Description: ============ NOTE: ************************************************************************ This patch does NOT conflict with CoreFLS and can be installed at CoreFLS sites. ************************************************************************* This patch updates outdated Surgery/HL7 Interface protocols in the Protocol file (#101) and the files used for the Surgery Interface in the HL LOGICAL LINK file (#870). ASSOCIATED NOIS: ================ OKL-0503-71174: Help w/SR*3*41 post-install NTH-1102-71197(duplicate): Problem with HL7 interface to Anesthesia instrument ASSOCIATED E3R: =============== N/A PARTICIPATING TEST SITES: ========================= North Texas Oklahoma City, OK North FL/South GA Iron Mountain, MI NOIS OVERVIEW: ============== PROBLEM: ======== The post-install instructions in patch SR*3.0*41 for setting up the HL protocols/devices is no longer applicable with the menu/option structure in HL package. Sites were unable to set up their Surgery/HL7 interfaces in the PROTOCOL file (#101) and the HL LOGICAL LINK file (#870). RESOLUTION: =========== Update the following Surgery protocols in the PROTOCOL file(#101) and the files in the HL LOGICAL LINK file(#870) for the Surgery interface to ensure that the ports are set correctly: HL LOGICAL LINK file (#870): SR AAIS SR SURGERY The PROTOCOL file (#101) will be updated through a post install routine SR122PST. This routine will ensure that the SENDING APPLICATION field (770.1), RECEIVING APPLICATION field (770.2) and the LOGICAL LINK field (770.7) are set correctly. This routine will also set the TIMESTAMP field (99) to the MUMPS date time for the install. The records affected are: SR Notification of Appointment Booking SR Notification of Appointment Cancellation SR Notification of Appointment Deletion SR Notification of Appointment Modification SR Notification of Appointment Rescheduling SR Other Master File Notification SR Query for Scheduling Information SR Receiver of Appointment Cancellation SR Receiver of Appointment Deletion SR Receiver of Appointment Modification SR Receiver of Appointment Rescheduling SR Receiver of Master File Notification SR Receiver of New Appointment Booking SR Receiver of Observation Unsolicited SR Receiver of Scheduling Query SR Receiver of Staff Master File Notification SR Receiver of Unsolicited Requested Observation SR Staff Master File Notification SR Unsolicited transmission of AAIS Requested Observation SR Unsolicited transmission of VistA Requested Observation ROUTINE SUMMARY: ================ The following is a list of the routine(s) included in this patch. The second line of each of these routine(s) will look like: ;;3.0;;Surgery ;**[Patch List]**;21 Nov 03 Routine name Before Patch After Patch Patch List ============ ============ =========== ========== SR122PST n/a 4075687 122 INSTALLATION INSTRUCTIONS ========================= Installation will take less than 2 minutes. 1. Choose the PackMan message containing this patch and invoke the INSTALL/CHECK MESSAGE PackMan option. 2. (DSM for Open VMS sites only) Disable routine mapping on all systems for the routines listed in the Routine Summary. NOTE: If the routines included in this patch are not currently in your mapped routine set, please skip this step. 3. Start up the Kernel Installation and Distribution System Menu [XPD MAIN]: Edits and Distribution ... Utilities ... Installation ... Select Kernel Installation & Distribution System Option: INStallation Load a Distribution Print Transport Global Compare Transport Global to Current System Verify Checksums in Transport Global Install Package(s) Restart Install of Package(s) Unload a Distribution Backup a Transport Global 4. From this menu, you may elect to use the following options (when prompted for the INSTALL NAME, enter SR*3.0*122): a. Backup a Transport Global - This option will create a backup message of any routines exported with this patch. It will not backup any other changes such as DD's or templates. b. Compare Transport Global to Current System - This option will allow you to view all changes that will be made when this patch is installed. It compares all components of this patch (routines, DD's, templates, etc.). c. Verify Checksums in Transport Global - This option will allow you to ensure the integrity of the routines that are in the transport global. 5. Use the Install Package(s) option and select the package SR*3.0*122. a. When prompted 'Want KIDS to INHIBIT LOGONs during the install? YES//', answer NO (unless otherwise indicated). b. When prompted 'Want to DISABLE Scheduled Options, Menu Options, and Protocols? YES//', answer NO 6. (DSM for Open VMS sites only) Optional - Include the routines distributed with this patch in the mapped routine set. NOTE: This step is only necessary if you performed step 2 or if you wish to include the routines in your mapped set. Routine Information: ==================== Routine Name: - SR122PST Routine Checksum: ============================================================================= User Information: Entered By : SMITH,ROBERT J Date Entered : AUG 05, 2003 Completed By: PEREZ,CAROL Date Completed: MAR 03, 2004 Released By : MUSGROVE,STEVE Date Released : MAR 04, 2004 ============================================================================= Packman Mail Message: ===================== $END TXT